– 27 –
Item
1. Ba
s
ic
operation
(continued)
1-2. When power
s
upply i
s
re
s
et
1) Distinction of outdoor unit
When the power supply is reset, the outdoors are distinguished and the
control is selected according to the distinguished result.
2)
S
etting of indoor fan speed and existence of air direction adjustment
Based on EEPROM data, select setting of the indoor fan speed and the
existence of air direction adjustment.
Air speed (rpm)/
Air direction adjustment
S
hift of suction
temperature in heating
operation
Operation flow and applicable data, etc.
De
s
cription
1-3. Operatin
g
mode
s
election when performin
g
2-room operation
1) The outdoor unit operation mode conforms to the instructions of the indoor unit that was pressed
first.
2) When combined operation consisting of cooling (dry) ,heating or fan only is performed, operation
conforms to the instructions of the indoor unit that was pressed first as shown in the following table.
3) The indoor fan stops for the indoor unit that was pressed last and which instructions are ignored.
4) When three or four indoor units are operated concurrently, the priority is also given to operating
mode of the indoor unit which was pressed first as same as the case when two indoor units are
operated concurrently.
No.
Indoor unit
S
et operatin
g
mode
Actual indoor unit operation
Actual outdoor unit operation
1-4. Room temp.control
1) Adjustment range: Remote controller setup temperature (˚C)
2) Using the Item code FC [06] the setup temperature in heating operation
can be corrected
S
etting at shipment
1
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Pressed first
Pressed last
Cooling (dry)
Cooling (dry)
Heating
Heating
Fan only
Fan only
Cooling(dry)
Heating
Cooling (dry)
Fan only
Heating
Cooling(dry)
Heating
Fan only
Fan only
Cooling(dry)
Fan only
Heating
Cooling (dry)
Cooling (dry)
Heating
Heating
Fan only
Fan only
Cooling (dry)
Fan stopped
Cooling (dry)
Fan only
Heating
Fan stopped
Heating
Fan stopped
Fan only
Cooling(dry)
Fan only
Fan stopped
Cooling
2
Heating
3
S
topped
4
Cooling
5
Cooling
6
Heating
7
Heating
8
Cooling
9
S
topped
Wired type
Wireless type
COOL/DRY
17 to 30
17 to 30
HEAT
17 to 30
17 to 30
AUTO
17 to 30
17 to 30
S
etup
S
etup temp. correction
0
+0˚C
2
+2˚C
4
+4˚C
6
+6˚C
S
etup data
2