– 35 –
Item
Operation flow and applicable data, etc.
Description
12. Self-Cleaning
function
• Self-Cleaning diagram
13. Self-Cleaning
function
release
How to cancel Self-Cleaning function
To cancel the Self-Cleaning function, proceed as follows:
• Press [TEMPORARY] button one time or use remote
control to turn on air conditioner. Display will show in
green color.
• Hold down the [TEMPORARY] button for more than 20
seconds. (The air conditioner will stop suddenly when
the [TEMPORARY] is pressed but keep holding it
continue.
• After holding about 20 seconds, the air conditioner will
beep 5 times without any blinking of display.
• The Self-Cleaning Operation had been cancelled.
How to set Self-Cleaning function
To set the Self-Cleaning function, proceed as follows.
• Press [TEMPORARY] button one time or use remote
control to turn on air conditioner. Display will show in
green color.
• Hold down the [TEMPORARY] button for more than
20 seconds. (The air conditioner will stop suddenly
when the [TEMPORARY] is pressed but keep holding
it continue.
• After holding about 20 seconds, the air conditioner will
beep 5 times and OPERATION display blinks 5
seconds.
• The Self-Cleaning function had been set.
14. Suction
temperature
correction
If difference between room temperature and Ta sensor
value is big, suction temperature shift by FC code setting
is available, refer to
14-2 Appendix Function selection
setup
.
Operation display
FCU fan
PRE, DEF display
Compressor
CDU fan
ON
OFF
OFF
ON
rpm is depend on presetting.
OFF
ON or OFF
depend on presetting per room temperature.
ON or OFF
depend on presetting per room temperature.
ON
(Self-Cleaning fan speed)
OFF
ON
OFF
OFF
OFF
OFF
OFF
Cool mode or dry mode
operation more than 10 mins.
Self-Cleaning mode
operate 30 mins.
Turn off by remote controller or
timer-off function.
Automatically turn-off.
Operation time
TEMPORARY
button
Содержание ras-m07g3dv-e