No.
Part name
P
rocedure
s
Remarks
Vertical louver
assembly
Cross flow fan
Vertical louver
Screw
Screw
Bearing base
Heat exchanger
Cross flow fan
3.5 mm
Cross flow fan
Set screw
Fan motor
Body back
Cross flow fan
Heat exchanger
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
3) Remove 4 fixing screws from the bearing
base then remove it from the main unit.
<To re-installation>
1) To incorporate the fan motor and the
motor into the position in the following
figure.
- Install the cross flow fan so that the right
end of the 1st joint from the right of the
Cross flow fan is keep 3.5mm from
closed wall of the main unit.
- Holding the set screw, install the
cross flow fan so that flat area on shaft of
the fan motor comes to the mounting hole
of the set screw.
4) Lift up the heat exchanger follow the figure.
Pull out the left hand side until the cross flow
fan is released from the shaft of the fan
motor and then pull out the lower side of
heat exchanger follow the figure.
8
9
1) Follow the procedure item 3 and 7 .
2) Remove 2 fixing screws from the base vertical
louver then remove the vertical louver
assembly from the body back.
FILE NO. SVM-19004
- 112 -
Содержание RAS-18J2AVG-EE
Страница 19: ...4 2 Outdoor Unit RAS 05 07 10 13J2AVG EE C L C L 280 400 Unit mm 280 300 FILE NO SVM 19004 19 ...
Страница 22: ...RAS 16J2KVG EE RAS 16J2AVG EE FILE NO SVM 19004 22 ...
Страница 23: ...RAS 18J2KVG EE RAS 18J2AVG EE FILE NO SVM 19004 23 ...
Страница 135: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...