Power supply input Wiring Diagram
1.
The power supply must be same as the rated of air conditioner.
2.
Prepare the power source for exclusive use with air conditioner.
3.
Circuit breaker must be used for the power supply line of this air conditioner.
4.
Be sure to comply power supply and connecting cable for size and wiring method.
5.
Every wire must be connected f rmly.
6.
Perform wiring works so as to allow a general wiring capacity.
7.
Wrong wiring connection may cause some electrical part burn out.
8.
Incorrect or incomplete wiring is carried out, it will cause an ignition or smoke.
9.
This product can be connected to main power supply.
Connection to fixed wiring : A switch which disconnects all poles and has a contact separation at least 3mm must be
incorporated in the fixed wiring.
CAUTION
Power supply input at Indoor unit Terminal Block (Recommend)
Power supply
input
L
N
GND
L N 1 2 3
Indoor
Terminal
Block
Out
door
Terminal
Block
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
CHASSIS
EARTH
1 2 3
Power supply input at Outdoor unit Terminal Block (Optional)
Power supply
input
GND
L
N
INDOOR UNIT
OUTDOOR UNIT
CHASSIS
Indoor
Terminal
Block
Out
door
Terminal
Block
CHASSIS
EARTH
L N 1 2 3
1 2 3 L N
FILE NO. SVM-19004
- 72 -
Содержание RAS-18J2AVG-EE
Страница 19: ...4 2 Outdoor Unit RAS 05 07 10 13J2AVG EE C L C L 280 400 Unit mm 280 300 FILE NO SVM 19004 19 ...
Страница 22: ...RAS 16J2KVG EE RAS 16J2AVG EE FILE NO SVM 19004 22 ...
Страница 23: ...RAS 18J2KVG EE RAS 18J2AVG EE FILE NO SVM 19004 23 ...
Страница 135: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...