2-2. Operation Characteristic Curve
<Cooling>
<Heating>
2-3. Capacity Variation ratio According to Temperature.
<Cooling>
<Heating>
0
1
2
3
4
5
6
7
0
10
20
30
40
50
60
70
80
90
100
Current (
A
)
Compressor Speed (RPS)
0
1
2
3
4
5
6
7
0
10
20
30
40
50
60
70
80
90
100
Current (
A
)
Compressor Speed (RPS)
RAS-16BKVG-E
RAS-13BKVG-E
RAS-10BKVG-E
RAS-07BKVG-E
RAS-05BKVG-E
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
0.0
20.0
40.0
60.0
80.0
100.0
120.0
-15
-10
-5
0
5
10
Heati
ng Capac
ity
r
ati
o
(%
)
Outside Temperature ( ºC)
RAS-16BKVG-E
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Cool
ing Capac
ity
r
ati
o (
%
)
Outside Temperature (
o
C)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C/WB 24
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
Capacity ratio : 100 %=
1.50kW(RAS-05BKVG-E)
2.00kW(RAS-07BKVG-E)
2.50kW(RAS-10BKVG-E)
3.30kW(RAS-13BKVG-E)
4.60kW(RAS-16BKVG-E)
RAS-05BKVG-E
RAS-07BKVG-E
RAS-13BKVG-E
RAS-10BKVG-E
RAS-16BKVG-E
Capacity ratio : 100 %=
2.00kW(RAS-05BKVG-E)
2.50kW(RAS-07BKVG-E)
3.20kW(RAS-10BKVG-E)
3.60kW(RAS-13BKVG-E)
5.40kW(RAS-16BKVG-E)
Conditions
Indoor : DB 20
o
C/WB 15
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Indoor Air Flow : High
Pipe Length : 5m
Voltage : 230V
FILE NO. SVM-16030
- 9 -
AMP Air Conditioning
www.ampair.co.uk | [email protected]