Item
Operation flow and applicable data, etc.
Description
Fan speed level
Cooling
Heating
Cool
Heat
Dry
Fan speed
Air flow rate
(rpm)
m
3
/s
Fan speed
Air flow rate
(rpm)
m
3
/s
WF
UH
1170
563
1170
707
WE
UH
H
1170
563
1170
707
WD
H
M+
UH
1110
524
1120
670
WC
M+
H
1060
491
1000
581
WB
M+
M+
950
419
880
492
WA
M
M+
850
353
880
492
W9
L+
850
353
750
395
W8
L+
L
L+
720
268
620
298
W7
L
L-
600
190
610
291
W6
L-
L
590
183
610
291
W5
UL
UL
L-
580
177
600
283
W4
UL
580
177
600
283
W3
SUL
SUL
540
151
520
224
W2
SUL
520
138
520
224
W1
500
125
500
209
Made
RAS-16BKVG-E
Fan speed level
Cooling
Heating
Cooling
Heating
Cool
Heat
Dry
Fan speed
Air flow rate
Fan speed
Air flow rate
(rpm)
m
3
/s
Fan speed
Air flow rate
(rpm)
m
3
/s
Fan speed
Air flow rate
(rpm)
m
3
/s
(rpm)
m
3
/s
WF
UH
1110
524
1110
663
1200
582
1200
730
WE
UH
H
1110
524
1110
663
1200
582
1200
730
WD
H
M+
UH
1060
491
1060
626
1170
563
1080
640
WC
M+
H
960
425
960
551
1120
530
1020
596
WB
M+
M+
870
367
870
484
1010
458
960
551
WA
M
M+
870
367
870
484
900
386
960
551
W9
L+
750
288
750
395
900
386
840
462
W8
L+
L
L+
640
216
640
313
770
301
720
373
W7
L
L-
600
190
600
283
640
216
660
328
W6
L-
L
600
190
600
283
620
203
660
328
W5
UL
UL
L-
570
170
570
261
600
190
600
283
W4
UL
570
170
570
261
600
190
600
283
W3
SUL
SUL
520
138
520
224
540
151
520
224
W2
SUL
520
138
520
224
520
138
520
224
W1
500
125
500
209
500
125
500
209
RAS-10BKVG-E
RAS-13BKVG-E
Made
2. Indoor fan
motor control
FILE NO. SVM-16030
-2
- 36 -
AMP Air Conditioning