34
Q9 ASD Installation and Operation Manual
Override Operation
The status of the listed control sources of
are read to determine which input sources are in the
Override Mode. The outcome is used for Command and/or Frequency control input.
The Override control setting supersedes the setting of the Command mode setting (
) and the
Frequency mode setting (
). However, the
and
settings will be used in the event that the
scan returns the condition that none of the listed items have the Override feature turned on (See
or a discrete input terminal is set to Local Priority and is activated.
Command and Frequency-Control Override Hierarchy
lists the input conditions and the resulting output control source selections for Command and
Frequency control Override operation. The Q9 ASD reads the command registers of the listed control
items from the left to the right.
The first item to be read that has the Override feature turned on will be used for Command or Frequency
control.
Table 3. Command and Frequency Control Hierarchy.
Forced F003/
F004 by I/P
Terminal
(Assign to Local
Priority)
Communication
Card
RS485
(4-Wire)
RS485
(2-Wire)
Panel
F003/F004
(Setting)
Actual Command/
Frequency Mode
1
X
X
X
X
X
F003/F004 Setting
0
1
X
X
X
X
Communication Card
0
0
1
X
X
X
RS232/485
0
0
0
1
X
X
Common Serial
0
0
0
0
1
X
Panel
0
0
0
0
0
1
F003/F004 Setting
Note:
1 = Override feature is active for that input; X = Don’t care; and 0 = Override Off
Содержание Q9 Series
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 217: ...Q9 ASD Installation and Operation Manual 207 Figure 28 See Table 13 and 14 for Actual Dimensions ...
Страница 218: ...208 Q9 ASD Installation and Operation Manual Figure 29 See Table 13 and 14 for Actual Dimensions ...
Страница 219: ...Q9 ASD Installation and Operation Manual 209 Figure 30 See Table 14 for Actual Dimensions ...
Страница 220: ...210 Q9 ASD Installation and Operation Manual Figure 31 See Table 13 and 14 for Actual Dimensions ...