2. Expanded Functions
2.2.3
Timer
The T3H has 1000 points of timer.
Function type
Type
code
Address range
Quantity
Expression
example
Timer register
T
000 - 999
1000 words
T670
Timer device
T.
000 - 999
1000 points
T.670
The proportion of the 0.01 s base and the 0.1 s base timers within this 1000 points
can be specified by user. This setting information is stored in the system information.
10 ms Timer Range Setting:
T000 - T [ ]
User setting (max. 999)
2.2.4
Link
register
The T3H has 2048 words of link register. This link register is prepared for the
TOSLINE-S20 (here called S20).
Function type
Type
code
Address range
Quantity
Expression
example
Link register
W
0000 - 2047
2048 words
W1500
Link device
Z
0000 - 999F
16000 points
Z847E
The link device Z corresponds to a bit in a link register W. The bit access as Z device
is available for the leading 1000 words of W register.
NOTE
T3H internally, the register ranges T000 to T511 and T512 to T999 are
handled separately. Therefore, index modification or table designation
across these ranges are not allowed.
For example)
├─
[ T450 TMOV (100) D1000 ]-
Not allowed
├─
[ T450 TMOV (62) D1000 ]-
Allowed
│
├─
[ T512 TMOV (38) D1062 ]-