2.5 USB FDD Troubleshooting
2 Troubleshooting Procedures
PORTÉGÉ M500 Maintenance Manual (960-559)
[CONFIDENTIAL]
2-37
Procedure 2
Diagnostic Test Program Execution Check
Insert the Diagnostics Disk in the USB FDD, turn on the computer and run the test. Refer to
Chapter 3,
Tests and Diagnostics,
for more information about the diagnostics test procedures.
Floppy disk drive test error codes and their status names are listed in Table 2-5. Make sure
the floppy disk is formatted correctly and that the write protect tab is disabled. If any other
errors occur while executing the FDD diagnostics test, go to Check 1.
Table 2-5 FDD error code and status
Code Status
01h
Bad command error
02h
Address mark not found
03h Write
protected
04h
Record not found
06h Media
removed
08h
DMA overrun error
09h
DMA boundary error
10h CRC
error
20h FDC
error
40h Seek
error
60h
Not drive error
80h
Time out error
EEh
Write buffer error
FFh
Data compare error
Check 1
If the following message appears, disable the write protect tab on the floppy disk.
If any other message appears, perform Check 2.
Write protected
Check 2
Make sure the floppy disk is formatted correctly. If it is, go to Procedure 3.
Содержание Portege M500
Страница 10: ...x CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 38: ...1 Hardware Overview 1 8 AC Adapter 1 24 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 39: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Страница 40: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 115: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Страница 116: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 3 ...
Страница 120: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 224: ...3 Tests and Diagnostics 3 30 SETUP 3 104 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 225: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Страница 226: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 230: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 319: ... CONFIDENTIAL Appendices ...
Страница 320: ...Appendices App ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 330: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 336: ...Appendices Appendix B Board Layout B 6 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 366: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 368: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 370: ...Appendices Appendix G BIOS rewrite procedures G 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 372: ...Appendices Appendix H EC KBC rewrite procedures H 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 374: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...