2 Troubleshooting Procedures
2.6 HDD Troubleshooting
2-40
[CONFIDENTIAL]
PORTÉGÉ M500 Maintenance Manual (960-559)
Procedure 2
Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed
in the BIOS ROM. When the test detects an error, an error message is displayed on the
screen.
Make sure no floppy disk is in the USB FDD. Turn on the computer and check the message
on the screen. When an OS starts from the 2.5” HDD, go to Procedure 3. Otherwise, start
with Check 1 below and perform the other checks as instructed.
Check 1
If any of the following messages appear, go to Procedure 3. If the following
messages do not appear, perform Check 2.
Built-in HDD ERROR
(After 5 seconds this message will disappear.)
or
CD-ROM ERROR
(After 5 seconds this message will disappear.)
Check 2
If either of the following messages appears, go to Check 3. If the following
messages do not appear, perform Check 4.
Insert system disk in drive
Press any key when ready .....
or
Non-System disk or disk error
Replace and press any key when ready
Check 3
Using the SYS command of the MS-DOS, transfer the system to the 2.5” HDD. If
the system is not transferred, go to Procedure 3. Refer to the MS-DOS Manual for
detailed operation.
If the following message appears on the display, the system program has been
transferred to the HDD.
System Transferred
If an error message appears on the display, perform Check 4.
Check 4
2.5” HDD(s) and the connector(s) of system board may be defective (Refer to the
steps described in Chapter 4,
Replacement Procedures
for disassembling.). Insert
HDD(s) to the connector(s) firmly. If it is (or they are) firmly connected, go to
Procedure 3.
Содержание Portege M500
Страница 10: ...x CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 11: ... CONFIDENTIAL Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 38: ...1 Hardware Overview 1 8 AC Adapter 1 24 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 39: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures ...
Страница 40: ...2 Troubleshooting Procedures 2 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 115: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics ...
Страница 116: ...3 Tests and Diagnostics 3 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 3 ...
Страница 120: ...3 Tests and Diagnostics 3 vi CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 224: ...3 Tests and Diagnostics 3 30 SETUP 3 104 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 225: ...Chapter 4 Replacement Procedures CONFIDENTIAL ...
Страница 226: ...4 Replacement Procedures 4 ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 230: ...4 Replacement Procedures 4 vi CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 319: ... CONFIDENTIAL Appendices ...
Страница 320: ...Appendices App ii CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 330: ...Appendices Appendix A Handling the LCD Module A 6 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 336: ...Appendices Appendix B Board Layout B 6 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 366: ...Appendices Appendix E Key Layout E 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 368: ...Appendices Appendix F Wiring diagrams F 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 370: ...Appendices Appendix G BIOS rewrite procedures G 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 372: ...Appendices Appendix H EC KBC rewrite procedures H 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...
Страница 374: ...Appendices Appendix I Reliability I 2 CONFIDENTIAL PORTÉGÉ M500 Maintenance Manual 960 559 ...