AIR CONDITIONER OPERATIONS AND
PERFORMANCE
Check before operation
• Check whether earth wire is disconnected or out of place.
• Check that air filter is installed to the indoor unit.
• Check that the air outlet or inlet is not blocked.
• Turn on the main power switch or the circuit breaker for the main power supply to the air conditioner.
Heating capacity
• For heating, a heat pump system which sucks in outside heat air and discharges it into the room is adopted.
If temperature of the outside air lowers, the heating capacity decreases.
• When temperature of the outside air is low, it is recommended to use other heating equipment together.
Defrost operation during heating operation
• If the outdoor unit has some frost during heating operation, the operation mode changes automatically to defrost mode to
increase the heating effect (for approx. 2 to 10 minutes).
• During defrost operation, fans of the indoor and the outdoor units stop.
3 minutes protection
• The outdoor unit does not operate for approx. 3 minutes after air conditioner has been immediately restarted after stop, or
power switch has been turned on. This is to protect the system.
Main power failure
• If a power failure occurred during the operation, all operations stop.
• When restarting the operation, push ON/OFF button again.
Fan rotation of stopped unit
• While other indoor units operate, the fan on indoor units on “stand-by” rotates to protect the machine once per approx.
1 hour for several minutes.
Protective device (High pressure switch)
The high pressure switch stops the air conditioner automatically when excessive load is applied to the air conditioner.
If the protective device works, the operation lamp keeps lit but the operation stops. When the protective device works, “
” in
the remote controller display part flash. The protective device may work in the following cases.
<Cooling operation>
• When the air inlet or air outlet of the outdoor unit is blocked.
• When strong wind blows continuously against the air outlet of the outdoor unit.
<Heating operation>
• When dust or dirt is excessively adhered to air filter of the indoor unit.
• When the air outlet of the indoor unit is blocked.
Cooling/heating operation of MiNi-SMMS air conditioner
In MiNi-SMMS air conditioner, each indoor unit can be individually controlled. However, cooling operation and heating
operation cannot be performed concurrently for the indoor units, which are connected to the same outdoor unit.
When cooling operation and heating operation are performed concurrently, the indoor unit which is performing cooling
operation stops, and the “
” on the unit display will be lit. The indoor unit that is in heating mode will continue operation.
If the manager has fixed the setting to COOL or HEAT, no other operation can be performed. When another operation other
than the set up one is performed, the “
” light is displayed on the display part of the indoor unit.
Characteristics of heating operation
• Hot air is not out immediately after the operation has started. After 3 to 5 minutes (differs according to room or outside
temperature) has passed and the indoor heat exchanger has been warmed up, hot air blows out.
• During operation, the outdoor unit may stop if outside temperature becomes high.
• When other outdoor unit performs heating operation while the fan is operating, the fan operation may be stopped
temporarily to prevent blowing of hot air.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Cooling operation
Heating operation
Outdoor temperature : –5°C to 43°C (Dry-bulb temp.)
Room temperature
: 21°C to 32°C (Dry-bulb temp.), 15°C to 24°C (Wet-bulb temp.)
CAUTION
Room relative humidity: less than 80 %. If the air conditioner operates
in excess of this figure, the surface of the air conditioner may cause dewing.
Outdoor temperature : –15°C to 15.5°C (Wet-bulb temp.)
Room temperature
: 15°C to 28°C (Dry-bulb temp.)
If air conditioner is used outside of the above conditions, safety protection may operate.
WARNING
Turn on the power switch 12 hours or more before starting
before operation.
Содержание MMU-AP0071MH
Страница 194: ...193 1 194 2 196 3 199 4 202 5 203 6 208 7 209 8 210 9 214 10 215 HFC R410A R22 China 1 ...
Страница 195: ...194 1 China 2 ...
Страница 196: ...195 1 China 3 ...
Страница 198: ...197 MMU AP0071YH AP0121YH MMU AP0152SH AP0182SH AP0242SH 2 China 5 ...
Страница 199: ...198 MMK AP0071H AP0241H MMK AP0073H AP0243H MMK AP0072H AP0122H China 6 ...
Страница 204: ...203 30 PRE HEAT 5 SWING FIX 4 China 11 ...
Страница 205: ...204 1H SWING 2H China 12 ...
Страница 208: ...207 1 2 1H 2H 3H 2SH 1 2 3 4 5 1YH 5 China 15 ...
Страница 210: ...209 7 1 m 80 China 17 ...
Страница 212: ...211 8 China 19 ...
Страница 213: ...212 1H 2H 3H 2H 3H 1 2 3 4 5 China 20 ...
Страница 214: ...213 8 China 21 ...
Страница 215: ...214 9 10 MiNI SMMS MiNI SMMS 12 5 C 43 C 21 C 32 C 15 C 24 C 80 15 C 15 5 C 15 C 28 C China 22 ...
Страница 216: ...215 10 ON OFF ON China 23 ...