– 49 –
CODE No.
Data name
Display format
Unit
Remote control display example
Indoor unit data *
3
Outdoor unit individual data 1 *
4
System
data
00
01
02
03
04
05
06
08
F3
0A
0B
0C
0D
Room temperature(Use to control)
Room temperature(Remote control)
Indoor suction air temperature (TA)*
1
Indoor coil temperature (TCJ)*
1
Indoor coil temperature (TC2)*
1
Indoor coil temperature (TC1)*
1
Indoor discharge air temperature (TF)*
2
Indoor PMV opening
Filter sign time
No. of connected indoor units
Total capacity of connected indoor units
No. of connected outdoor units
Total capacity of connected outdoor units
×1
×1
×1
×1
×1
×1
×1
×1/10
×1
×1
×10
×1
×10
°C
°C
°F
°F
°F
°F
°F
pls
h
unit
ton
unit
ton
[0027] = 27°C
[0080] = 80°F
[0150] = 1500pls
[2500] = 2500h
[0048] = 48units
[0215] = 21.5ton
[0003] = 3units
[0160] = 16ton
CODE No.
Data name
Display format
Unit
Remote control display example
U1
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
U2
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
High-pressure sensor detention pressure (Pd)
Low-pressure sensor detention pressure (Ps)
Compressor 1 discharge temperature (TD1)
Compressor 2 discharge temperature (TD2)
Compressor 3 discharge temperature (TD3)
Suction temperature (TS1)
Outdoor coil temperature (TE1)
Outdoor coil temperature (TE2)
Outdoor coil temperature (TL)
Outside ambient temperature (TO)
PMV1,2 opening
PMV4 opening
Compressor 1 curent (I1)
Compressor 1 curent (I2)
Compressor 1 curent (I3)
×10
×10
×1
×1
×1
×1
×1
×1
×1
×1
×1
×1
×10
×10
×10
psi
psi
°F
°F
°F
°F
°F
°F
°F
°F
pls
pls
A
A
A
[4350] = 435 psi
[0080]= 80 °F
[0500] = 500pls
[0135] = 13.5A
Outdoor unit individual data 2 *
4
CODE No.
Data name
Display format
Unit
Remote control display example
U1
50
51
52
53
54
55
56
57
58
5B
5D
5E
U2
60
61
62
63
64
65
66
67
68
6B
6D
6E
–
–
–
–
–
–
–
–
–
–
–
–
–
Compressor 1 revolutions
Compressor 2 revolutions
Compressor 3 revolutions
Outdoor fan mode
Compressor IPDU 1 heat sink temperature
Compressor IPDU 2 heat sink temperature
Compressor IPDU 3 heat sink temperature
Outdoor fun IPDU 1 heat sink temperature
Heating/cooling recovery controlled
Pressure release
Pressure release
Follower unit release (U2/U3 outdoor units)
0:Normal
1:Release controlled
[0642] = 64.2rps
×10
×10
×10
×1
×1
×1
×1
×1
rps
rps
rps
mode
°F
°F
°F
°F
[0500] = 500pls
[0024] = 24 °F
[0010]=Heating recovery controlled
[0010]=Pressure release controlled
[0001]=Discharge temperature release controlled
[0100]=U2 outdoor unit release controlled
0:Normal
< Based on the SMMS-i >
*1 The Outside Air Unit uses the revised sensor data, therefore the data below are not correctly displayed
because they are revised sensor data.
Indoor suction air temperature (TA)
Indoor coil temperature (TCJ)
Indoor coil temperature (TC2)
Indoor coil temperature (TC1)
*2 Only a part of indoor unit types is installed with the discharge air temperature sensor. This temperature is
not displayed for other types.
*3 When the units are connected to a group, data of the header indoor unit only can be displayed.
*4 The indications, U1, U2, U3 indicate the following outdoor units, respectively. For the indication data of each
outdoor unit, check CODE No.
U1...outdoor unit (Header unit)
U2...outdoor unit (Follower unit 1)
U3...outdoor unit (Follower unit 2)