IPedge General Description 01/12
95
Appendix – Specifications
This appendix includes detailed information on the items listed below. The sections in this
appendix apply to the IP
edge
systems, unless otherwise stated.
•
•
•
IPedge Component Compatibility
•
•
•
IPedge Net and IP Telephone Bandwidth Requirements
•
IPedge Net and IP Telephone Bandwidth Requirements
•
For further details, refer to the
IPedge I&M Manual.
Operating Environment.
Table 4
Operating Environment
EC Server
EM Server
EP Server
Operating
Temperature
50
0
F ~ 95
0
F; 10
0
C ~ 35
0
C 50
0
F ~ 95
0
F; 10
0
C ~ 35
0
C 50
0
F ~ 95
0
F; 10
0
C ~ 35
0
C
Operating Humidity
20% ~ 80%
(non condensing)
20% ~ 80%
(non condensing)
20% ~ 80%
(non condensing)
Storage Temperature
-20 ~ +60
0
C
-20 ~ +60
0
C
-20 ~ +60
0
C
Power
100 ~ 240 VAC; 50 ~ 60 Hz;
1.2 Amp at 120 VAC; 130
Watts
Inrush Current: 11.5 Amp
100 ~ 240 VAC; 50 ~ 60 Hz,
2.1 Amp at 120 VAC; 250
Watts
Inrush Current: 10.4 Amp
The IP
edge
EM server has
two redundant, hot-swap
power supplies.
The server can run
indefinitely on one supply.
100 ~ 240 VAC; 50 ~ 60 Hz;
In-rush: Maximum 10 Amp
(cold start)
Peak Load: 0.4 Amp
Heat
785 BTUs
778 BTU/hour; 867 BTUs
max.
106 BTUs
Содержание ID EDGE
Страница 1: ...TOSHIBA Telecommunication Systems Division January 2012 General Description Title Page ...
Страница 6: ...This page is intentionally left blank ...
Страница 12: ...This page is intentionally left blank ...
Страница 24: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 134: ...This page is intentionally left blank ...
Страница 142: ...This is the last page of the document ...