113
DP-1910F
4.4.3.
Document Jam (030) or Skew
Copy Mode
Sample
END
START
Close the ADF Unit firmly.
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Is the ADF Unit closed?
Clean, or replace Sensor PCB.
Do all sensors
operate normally?
Clean the surface of roller
with water.
Does the Feed Roller have
drive, and sufficient friction?
Remove the foreign particles
or papers from the document
path.
Is the document path clear
of foreign particles, or paper?
Adjust, or replace any
defective parts.
Is the Transmitting
mechanism operating
properly?