163
DP-1910F
5.2.3.
Fax Service Mode 1 (Function Parameter Setting)
Use the following procedure to change the function parameters.
Enter the desired code number and press the
“Start”
key.
If you wish to select another code number, press the
“
”
,
“
”
keys.
↓
Select the desired function code and press the
“Start”
key.
When the
“Clear”
key is pressed, the selected code input will not be accepted.
↓
Press the
“Stop”
key.
↓
Press the
“Stop”
key to exit the service mode.
Function Parameter Table
No.
Parameter
Selections
Function
000
MON/TEL DIAL
1 = Monitor
2 = Tel/Dial
Selects whether the machine starts to TX
automatically during On-Hook dialing.
Monitor
: Start to TX after pressing Start
TEL/DIAL
: Start to TX automatically
001
ALARM STATUS
1 = Off
2 = Timer
3 = Constant
Selects the No Paper or No Toner alarm status.
OFF
: Alarm is disabled.
Timer
: Alarm will shut off after 6 seconds.
Constant
: Alarm will not stop until “Stop” is pressed
or the error is cleared/corrected.
002
STOP COMM.
JRNL
1 = Off
2 = On
Selects whether the machine prompts to print the
COMM. Journal when the printout condition is set to
INC and Stop is pressed during communication.
003
CONTINUOUS
POLL
1 = Off
2 = Stn (Tx only)
3 = Hub (Rx only)
Selects whether the Continuous Polling feature is
enabled.
Stn
: Place the document(s) on the ADF, then press
the assigned One-Touch Key to store or add
the documents into a polled file.
(
See Note 1
)
Hub
: When the polling command is initiated, the
machine will continuously poll originals from
the remote stations until it is interrupted by
pressing "Stop".
004
NUMERIC ID
SET
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts and allows to
set or change the Numeric ID.
006
ID DISPLAY
1 = Number (Numeric ID)
2 = Chara (Character ID)
3 = Name (Station Name)
4 = Dial (Dialing Number)
Selects the priority of displaying/Printing the ID,
Name or Dialing Number. (Default : 3 = Name)
1 = Number : Number>Name>Chara>Dial
2 = Chara
: Chara>Name>Number>Dial
3 = Name
: Name>Chara>Number>Dial
4 = Dial
: Dial>Name>Chara>Number
007
Not Used
008
MONITOR
1 = Off
2 = On
Selects whether the Monitor is ON/OFF for
monitoring fax signals. The 2nd G3 port is also
available.
(FOR SERVICE USE ONLY)
009
DC LOOP
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back to back
communication test.