e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
05
M
Judges the presence of the developer unit-K. If it is
judged as present, the input of this code will be
refused. (Unit: bit)
To perform this code, disconnect all the auto-toner
sensors in the EPU.
Adjustment
mode
Process
Charger
Main charger grid
bias adjustment
2462
73
0~255
3
M
05
C
Judges the presence of the developer unit-K. If it is
judged as present, the input of this code will be
refused. (Unit: bit)
To perform this code, disconnect all the auto-toner
sensors in the EPU.
Adjustment
mode
Process
Charger
Main charger grid
bias adjustment
2463
73
0~255
3
M
05
K
Judges the presence of the developer unit-K. If it is
judged as present, the input of this code will be
refused. (Unit: bit)
To perform this code, disconnect all the auto-toner
sensors in the EPU.
Adjustment
mode
Process
Charger
Main charger grid
bias adjustment
2464
73
0~255
3
M
05
Lower limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
Y
2627
0
100
0~1000
4
Yes
M
05
Upper limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
Y
2627
1
900
0~1000
4
Yes
M
05
Lower limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
M
2628
0
100
0~1000
4
Yes
M
05
Upper limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
M
2628
1
900
0~1000
4
Yes
M
05
Lower limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
C
2629
0
100
0~1000
4
Yes
M
05
Upper limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
C
2629
1
900
0~1000
4
Yes
M
05
Lower limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
K
2630
0
100
0~1000
4
Yes
M
05
Upper limit
(Unit: V)
Adjustment
mode
Process
Developer
Developer bias
DC(-) calibration
voltage
K
2630
1
900
0~1000
4
Yes
M
05
Y
Use this code to increase/decrease the image
density. After changing the setting value of this
code, perform 05-2742.
Adjustment
mode
Process
Developer
Target value for
high density
control
2662
0
312
0~999
4
M
05
M
Use this code to increase/decrease the image
density. After changing the setting value of this
code, perform 05-2742.
Adjustment
mode
Process
Developer
Target value for
high density
control
2662
1
316
0~999
4
M
05
C
Use this code to increase/decrease the image
density. After changing the setting value of this
code, perform 05-2742.
Adjustment
mode
Process
Developer
Target value for
high density
control
2662
2
316
0~999
4
M
05
K
Use this code to increase/decrease the image
density. After changing the setting value of this
code, perform 05-2742.
Adjustment
mode
Process
Developer
Target value for
high density
control
2662
3
340
0~999
4
M
2
Ver11
05 Adjustment Mode
Содержание E-Studio 5540c
Страница 34: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 1254: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 56 ...
Страница 1266: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 12 ...