8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 317
8.5.15
Color banding (in feeding direction)
Fig.8-23
Cause/Section
Step
Check item
Measures
Laser optical
unit, Main
charger grid
1
Perform the enforced performing of
image quality closed-loop control (05-
2742).
When the enforced performing of
image quality closed-loop control is
performed, the automatic cleaning of
main charger and the LSU slit glass
cleaning are performed at the same
time.
Scanner
2
Is there foreign matter in the optical
path?
Clean the slit, lens and mirrors.
3
Is there dust or stain on the shading
correction plate or ADF original
glass?
Clean it.
Main charger
4
Is there foreign matter on the charger
grid?
Remove foreign matter.
5
Is the charger grid dirty or deformed? Clean or replace the charger grid.
6
Is there foreign matter on the main
charger?
Remove foreign matter.
7
Is the needle electrode dirty or
deformed?
Clean or replace the needle
electrode.
8
Is the needle electrode cleaner dirty
or deformed?
Clean or replace the needle electrode
cleaner.
9
Is the inner surface of charger case
dirty?
Clean inside.
Drum cleaner
10
Is there any foreign matter on the
drum cleaning blade edge?
Clean or replace the drum cleaning
blade.
11
Is toner recovery defective?
Clean the toner recovery auger
section.
Feeding direction
Содержание E-Studio 5540c
Страница 34: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved FEATURE 1 2 ...
Страница 1254: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved FIRMWARE UPDATING 11 56 ...
Страница 1266: ...e STUDIO5540C 6540C 6550C 5560C 6560C 6570C 2011 2015 TOSHIBA TEC CORPORATION All rights reserved BACKUP FUNCTION 12 12 ...