6
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
SETTING ADJUSTMENT
6 - 87
* If the roller life is not improved or the multiple
feeding is not suppressed with the adjustment in
step (6), perform the following procedure in steps
(8) through (10).
(8) Remove 1 screw from the round hole of the
rear side bracket [1], and screw it temporarily
to an oblong hole.
Fig.6-40
(9) Move the rear side bracket [1].
Move to the direction A: The roller life will
become longer (but multiple feeding may
occur frequently).
Move to the direction B: Multiple feeding will
be suppressed (but the roller life may
become shorter).
Notes:
The recommended moving distance of the
bracket is within 1 or 2 scale marks.
(10) Tighten the screw that was temporarily
screwed.
Fig.6-41
[1]
B
A
[1]