7
–
100
95
90
85
80
75
70
65
60
55
50
105
90
91
93
95
97
99
100
102
104
106
108
109
111
113
115
Capacity Ratio (%)
Capacity Ratio: 100% =
9000 Btu/h (RAS-09
E
K
C
V-UL)
12000 Btu/h (RAS-12
E
K
C
V-UL)
RAS-09
E
K
C
V-UL
RAS-12
E
K
C
V-UL
<Cooling>
2-3. Capacity Variation Ratio According to Temperature
<Cooling>
FILE NO. SVM-13071
0
1
2
3
4
5
6
7
8
0
10
20
30
40
50
60
70
80
90 100 110 120
Compressor Speed (rps)
Cur
re
nt (A)
Conditions
Indoor : DB 80
o
F/WB 67
o
F
(DB 26.7
o
C/WB 19.4
o
C)
Outdoor : DB 98
o
F/WB 75
o
F
(DB 35
o
C/WB 23.9
o
C)
Indoor Air Flow : High
Pip Length : 5m
Voltage : 230V
RAS-09EKCV-UL
RAS-12EKCV-UL
Condition
Indoor: DB80°F/WB67°F
Indoor Air-Flow Volume: High
Pipe Length: 16 ft (5m)
(DB26.7°C/WB19.4°C)
Voltage : 230V
Outdoor Temperature [°F(°C)]
(32)(33)(34)(35)(36)(37)(38)(39)(40)(41)(42)(43)(44)(45)(46)
2-2. Operation Characteristic Curve