LCD DISPLAY SCREEN

1

2

3

4

5

6

7

8

9

1.

CONNECTED ELIMINATOR INDICATOR: appears when the battery

eliminator is connected to the scale and in turn this is connected to a

110/220VAC outlet.

2. ACTIVE

“ALARM”

INDICATOR: means that a weight range has been set

for the alarm.

3.

“ZERO”

INDICATOR: Shown when the weight on the plate is zero.

4. "NET" INDICATOR: indicates that the "tare" function has been activated.

the readings shown correspond to the net weight.

5.

“LOW”

INDICATOR: Indicates that the weight on the plate is less than

the lower limit of the interval set for the alarm.

6.

“HIGH”

INDICATOR: Indicates that the weight on the plate is greater

than the upper limit of the interval set for the alarm.

7. WEIGHT UNIT INDICATOR: Displays the selected weight unit.

8. ALPHANUMERIC INDICATOR: Displays the weight and messages of the

scale.

9. LOW BATTERY INDICATOR: appears when the battery power is low and

indicates that it is necessary to recharge it.

8

L-EQ HS Series

Содержание L-EQ 10/20-HS

Страница 1: ...REV 0 CODE 13100907 OWNER S MANUAL PORTIONING SCALE BEFORE OPERATING THIS SCALE PLEASE READ THIS MANUAL THOROUGHLY L EQ HS Series ...

Страница 2: ...to use the backlight How to use the alarm function PC communication How to display weight measure on PC screen Format of the data sent to the PC Using Scale software Power timer function Low battery indicator Use of the battery Other important messages that appear on the scale Maintenance and cleaning Troubleshooting guide Technical specifications Additional data 3 5 5 6 7 8 9 9 9 9 9 10 10 10 11 ...

Страница 3: ... avoiding overloads or voltage variations 5 Do not wash the scale using flow of water This can damage the electronic components For more information read Maintenance and cleaning section 6 Protect the scale from insects they can damage the electronic components Use online solid products against insects 7 Do not drop or hit the scale with the product to be weighted this will damage the weight senso...

Страница 4: ...y authorized and qualified personnel should inspect and repair the scale 4 WARNING Do not open the scale Caution to reduce the risk of short circuit in your scale do not remove the cover or substitute any of the parts for others that are not original only authorized distributor Battery should be recharged for 10Hrs before using the scale for the first time IMPORTANT IMPORTANT WARNINGS L EQ HS Seri...

Страница 5: ...ossible that the scale shows HELP when it is lit with a product on the plate in this case remove the weight from the scale turn it off and then on again 1 Unpack the scale and check that it is in good condition If you find any damage notify your authorized dealer immediately 2 Place the scale in a place free of movements and vibrations make sure it is level checking that the four leveling feet hol...

Страница 6: ...le keyboard 5 DISPLAY Liquid crystal 6 ADJUSTABLE LEVELING FEET Loose or tight up them to adjust the scale 7 JACK DC power supply connection located in the scale s base 8 LEVEL INDICATOR Used as a scale s leveling reference 9 POWER SUPPLY 110VAC 6VDC or 220VAC 6VDC included 10 RS232 CONNECTOR To connect the scale with a PC or printer using a RS232 cable 11 TARE FOOTSWITCH CONNECTION To connect the...

Страница 7: ...n through RS232 Activate the TARA function Activate the ZERO function Show the weight in kg Show the weight in lb Show the weight in oz Increase the weight to be set for the weight alarm Decrease the weight to be set for the weight alarm Activates and sets the weight alarm 7 Portioning Scale ...

Страница 8: ...tion has been activated the readings shown correspond to the net weight 5 LOW INDICATOR Indicates that the weight on the plate is less than the lower limit of the interval set for the alarm 6 HIGH INDICATOR Indicates that the weight on the plate is greater than the upper limit of the interval set for the alarm 7 WEIGHT UNIT INDICATOR Displays the selected weight unit 8 ALPHANUMERIC INDICATOR Displ...

Страница 9: ...e weight from the container and press the TARE key again 9 The unit s keys allow you to weight a product in kilograms pounds or ounces If you weight a product in pounds and want to convert that weight into kilograms just press the kg key and the scale will convert it automatically When you press the PRINT key the scale will send the data shown in the display to a PC To activate this function the s...

Страница 10: ...IT key to save the alarms limits and start weighting 10 How to use REFERENCE ZERO If the scales shows weight in the display without having any product over it may be caused by voltage variations rough use etc In this case press the ZERO key and the display will return back to zeros How to use the backlight In case of having not enough light for a optimum visibility use the scale s backlight to imp...

Страница 11: ...alent on ASCII code from the computer Scale will send a weight measure CC control character Weight CR Portioning Scale Usually through the computer the data following are sent in ASCII and hexadecimal code Control character CC is equal to OD in all examples To be able to transmit the scale s data to your computer please follow these steps Format of the data sent to the PC How to display weight mea...

Страница 12: ...loads In section PPT Torrey Software Steps to establish communication with the PC using the Scale software Select Configuración Puerto Serial choose a Baud Rate 9600 bps recommended and the Port which your computer recognized the scale Select Conectar and next Empezar Secuencia immediately you would see the weight on your PC screen in real time To stop the communication select Desconectar 12 L EQ ...

Страница 13: ...ed when the scale is turned on without the AC DC power supply When the sale is not used during approximately 15 minutes it will automatically be turned off USE OF THE BATTERY The scale can operate using the rechargeable battery 4 VDC Included or with the AC DC power supply The battery is recharged by being connected with the AC DC power supply during approximately 10 hours with the scale turns off...

Страница 14: ... on the plate near half the scale s capacity To correct this situation remove the weight on the scale turn the scale off and then back on again 2 When the scale has been handled roughly and or hit OVER LOAD HELP This message indicates a negative weight to fix this place back in its plate and press the 0 key or turn the scale off and then turn it back on again NEG This message appears when the batt...

Страница 15: ...r the plate or under the plate holder that could obstruct the adequate operation of your scale Periodically check the jack where the AC DC power supply in inserted to make sure it is in good condition that is check there are not sings of strokes or detachments Periodically check the AC DC power supply to make sure the ends are in good condition and that the cable is not twisted or tangled Regular ...

Страница 16: ...eck the AC DC power supply terminals if it is possible check with another AC DC power supply Low battery Connect the AC DC power supply and verify that the battery is been recharged If not replace the battery The scale shows different weights with the same product Material under the plate Check if exists materials under the platform If so remove them and check the operation again The word HELP app...

Страница 17: ...g MIN DIV 0 002kg 0 005lb 0 1oz MAX TARE 10kg 20lb 320oz OPER TEMP 14 F to 104 F MAX MAXIMUM CAPACITY MIN MINIMUN CAPACITY MAX TARE MAXIMUM TARE OPER TEMP OPERATING TEMPERATURE POWER SUPPLY INPUT 110 220VAC POWER SUPPLY OUTPUT 6VDC 500mA BATTERY 4VDC 2 5A h NOTE BATTERIES CAN ONLY BE RECHARGED FROM 32ºF TO 104ºF STORAGE TEMPERATURE 4 F TO 122 F Portioning Scale 17 5 118 9 645 10 039 ...

Страница 18: ...______ Serial number ___________________________________________ We reserve the right to change any specification contained in this text without prior notice 18 The serial number of this product can be found in the identification information which is located at the top of the scale s cabinet We suggest you that write the serial number and the scale model in the following spaces and hold them as pr...