Error messages
Display
Cause
What to do
E21
Incorrect calibration of accelerator lever
Recalibrate:
1. Press the CAL button for 10 seconds.
cal up
appears on the display.
2. Set the accelerator lever to full throttle forwards.
3. Press the CAL button.
cal stp
appears on the display.
4. Set the accelerator lever to the neutral (stop) position.
5. Press the CAL button.
cal dn
appears on the display.
6. Set the accelerator lever to full throttle reverse.
7. Press the CAL button.
E22
Magnetic sensor defective
Recalibrate;
see "E21"
. If the error code appears several times, then con-
tact Torqeedo Service.
E23
Value range incorrect
Recalibrate;
see "E21"
.
E30
Communication error with motor
Check the cables and the plug connections of the data cables.
If necessary, contact Torqeedo Service and tell them the error code.
E32
Communication error for accelerator lever
Check the plug connections of the data cables.
Check the cables.
E33
General communication error
Check the plug connections on the cables.
Check the cables.
Switch the motor off and on again.