Care and service
DE
EN
page 45 / 117
8.3 Maintenance intervals
If the prescribed maintenance intervals are not complied with or documented, the guarantee and warranty become void. Ensure that the services carried out are documented
in your service check folder.
Check by the customer before every use
Component
Activity
Emergency Stop Switch
Check functionality
Complete system
Visual inspection of all components
Cooling systems
Check/clean filters
Pumps
Check flow
Connections/hoses
Check for leaks
Check attachment
Venting of high-voltage battery (op-
tional)
Check draining openings
Check by the customer (O) or by Torqeedo technician (X)
Overall system
Activity
1000 h/annually
Special intervals
All system components
Check attachment
O
Motor and battery
Check fastening and torque of screws, bolts
X
Check seal of cable glands
X
Confirm full insulation
X
Cable connections for HV, 12 V, 24 V, data
Visual inspection of all HV connections
X