g336408
Figure 115
Note:
The engine will not crank over when the PTO switch is in the ON position.
All switches are supplied in parallel and feed into the Hour Meter.
PTO Switch Test
1. Remove the control panel from the right console.
2. Disconnect the PTO switch from the wire harness.
3. With the switch in the ON position (button pulled OUT).
g336409
Figure 116
4. Using a digital multi-meter set to the OHM or Continuity setting, verify the
following:
• Pin 2 and 5 should have continuity (closed)
• Pin 1 and 4 should have continuity (closed)
• Pin 1 and 7 should NOT have continuity (open)
• Pin 2 and 8 should NOT have continuity (open)
5. With the switch in the OFF position (button pushed IN):
• Pin 1 and 7 should have continuity (closed)
• Pin 2 and 8 should have continuity (closed)
• Pin 1 and 4 should NOT have continuity (open)
TITAN® Max Service Manual
Page 8–9
Electrical System: Service and Repairs
3442-428 Rev A
Содержание TITAN
Страница 2: ...Revision History Revision History Page 2 TITAN Max Service Manual 3442 428 Rev A ...
Страница 6: ...Preface Page 6 TITAN Max Service Manual 3442 428 Rev A ...
Страница 20: ...Specifications and Maintenance Torque Specifications Page 2 10 TITAN Max Service Manual 3442 428 Rev A ...
Страница 26: ...Troubleshooting General Troubleshooting Page 3 6 TITAN Max Service Manual 3442 428 Rev A ...
Страница 36: ...Engine Service and Repairs Page 4 10 TITAN Max Service Manual 3442 428 Rev A ...
Страница 70: ...Chassis Service and Repairs Page 5 34 TITAN Max Service Manual 3442 428 Rev A ...
Страница 92: ...Mower Deck Service and Repairs Page 6 22 TITAN Max Service Manual 3442 428 Rev A ...
Страница 118: ...Electrical System Service and Repairs Page 8 18 TITAN Max Service Manual 3442 428 Rev A ...
Страница 121: ... Drawing Rev A Sheet 1 3442 428 Rev A Page A 3 Kohler Engine Electrical Schematic g350654 ...