g387135
Figure 21
1.
Left tank return valve
(close position)
3.
Right tank suction valve
(open position)
2.
Left tank suction valve
(close position)
4.
Right tank return valve
(open position)
Selecting Both Spray Tanks
Rotate the valve handles as shown in
g387108
Figure 22
1.
Left tank return valve
(open position)
3.
Right tank suction valve
(open position)
2.
Left tank suction valve
(open position)
4.
Right tank return valve
(open position)
Spraying
Spraying Tips:
•
Do Not overlap the effective spray area that was
previously sprayed.
g312650
Figure 23
1.
Overlap area
2.
Effective spray area
•
Watch for plugged nozzles.
•
Disengage spray control levers to stop the spray
flow before stopping the motion of the sprayer.
Once stopped, leave the motion control lever in
neutral and keep the pump running.
•
Better results are obtained if the sprayer is moving
when spray controls are turned on.
•
Watch for changes in the application rate that may
indicate that your speed has changed beyond the
range of the nozzles or there is a problem with the
spray system.
Note:
Make sure the machine has been calibrated
properly before starting spray application
1.
Make sure the spray pump is on.
2.
Drive to the work area to be sprayed.
3.
Adjust the spray pressure to the appropriate
setting.
4.
Turn on the appropriate spray control:
The sprayer and spreader can be operated
either together or individually (spray liquid and
spread granular at the same time or separately).
Regardless of the situation, make sure that the
machine is running at full throttle.
When finished spraying, turn off the spray
control lever and the spray pump switch.
The spray pump switch can be left on for tank
agitation.
To use the spray wand: