Transferring Fluid Between Tanks
Transferring Fluid from the Left Tank to the
Right Tank
1.
Ensure that the right tank has capacity to hold
fluid from the left tank.
2.
Ensure that the handles for the spray-control
valves are in the
OFF
position (
g311519
Figure 36
1.
Spray-control valve (left
boom)
3.
Spray-control valve (right
boom)
2.
Spray-control valve
(center boom)
3.
Loosen the locknut, and open the throttle valve
(
).
g311521
Figure 37
1.
Locknut
2.
Throttle valve knob
4.
Rotate the valve handles as shown in
g311516
Figure 38
1.
Left tank return valve
(
CLOSE
position)
3.
Right tank suction valve
(
CLOSE
position)
2.
Left tank suction valve
(
OPEN
position)
4.
Right tank return valve
(
OPEN
position)
5.
Press the sprayer-pump switch to the
ON
position (
g317872
Figure 39
1.
Sprayer-pump switch
6.
When the quantity of fluid is transferred to the
right tank, press the sprayer-pump switch to the
OFF
position.
Transferring Fluid from the Right Tank to the
Left Tank
1.
Ensure that the left tank has capacity to hold
fluid from the right tank.
2.
Rotate the valve handles as shown in