g010803
Figure 10
1.
Damage will occur here.
7
Checking the PTO Angle
No Parts Required
Procedure
Important:
Before checking the PTO angle,
remove the tines.
1.
With the aerator positioned on the ground and
lowered to the deepest location, use an angle
indictor to measure the angle between the PTO
and the aerator.
2.
Lift the aerator and fully retract the hydraulic top
link cylinder.
3.
Using an angle indictor, check the angle
between the PTO and the aerator.
4.
If your measurement is greater than 35°, perform
1 of the following to adjust the traction unit so
that you cannot raise the aerator past 35°.
•
Use the lift stop of the traction unit (if
equipped).
•
Move the lower links to a higher mounting
hole (if equipped).
8
Fitting the PTO Shaft
Parts needed for this procedure:
1
PTO shaft
Procedure
1.
Park the traction unit and aerator on a level
surface.
2.
Raise the aerator completely and fully retract the
hydraulic top link cylinder or upper link (
g010798
Figure 11
3.
Measure the distance from the locking groove
at the end of the traction unit PTO shaft to the
locking groove at the aerator gearbox shaft
(
).
Record this measurement here:
E
XAMPLE
: 67
CM
(26-1/2
INCHES
)
g237884
Figure 12
1.
Measure here
2.
Locking groove
4.
Lower the aerator to the ground and fully extend
the hydraulic top link cylinder or upper link
(
).
13