background image

spreader housing, indicate the operating arc of the
spreader spout.

(–) or MIN = A spout arc of 38 degrees
(+) or MAX = A spout arc of 58 degrees

Adjust the arc of the spout action as follows:

1.

Turn the spreader drive pulley by hand, until the arc
adjuster appears in the opening in the spreader, as
shown in Fig. 5.

Fig. 5

1. 

Flow control handle

2. 

Flow regulator scale

3. 

Spout arc adjustment

2. 

Using the wrench furnished, loosen the two locking
nuts on each side of the arc adjuster.

3.

Insert the opposite end of the wrench into the open-
ing and turn the adjuster to the desired spreading
width.

4. 

Re-tighten the locking nuts.

IMPORTANT: When spreading sand, the spout arc
must be at the "–" or MIN. setting.

The table below gives some suggested spread widths and
spout arc settings for a variety of materials.

MATERIAL

SPREAD WIDTH

SPOUT ARC

Granulated

40 ft. (12m)

– (Min)

Prilled

40 ft. (12m)

+ (Max)

Powdered

20 ft. (6m)

(Midway)

Urea

32 ft. (10m)

+ (Max)

The spreader unit can be fitted with two different spouts.
The smaller metal spout (packed with the spreader
mounting kit) is recommended for spreading sand.  The
longer nylon spout is recommended for spreading fertil-
izer.

SPREADER CALIBRATION

To calibrate the TORO spreader you must determine the
desired rate of flow for the material being applied (in
pounds per acre), as specified by the material's manufac-
turer.

To achieve this application rate, first establish the fol-
lowing:

1. 

The spread width, for the material being applied.  

NOTE: This width will vary depending on the den-
sity of the material and the spout arc setting.

2. 

The flow rate of material from the hopper, in Kg.
per acre.  This will depend on the particle size of
the material and the position of the flow regulator
setting.

4

Содержание PA-17

Страница 1: ...safety instructions that follow IMPORTANT identifies special mechanical information and NOTE identifies general information worthy of special attention These instructions are provided as a guide for t...

Страница 2: ...ny shields removed during ser vicing or adjustments 9 To be sure of optimum performance and safety always purchase genuine TORO replacement parts and accessories Replacement parts and accessories made...

Страница 3: ...w Regulator FLOW CONTROL HANDLE Opens and closes the regulator disc in the hopper opening to start or stop the flow of material Pull the handle forward toward the operator to open the regulator disc P...

Страница 4: ...rc settings for a variety of materials MATERIAL SPREAD WIDTH SPOUT ARC Granulated 40 ft 12m Min Prilled 40 ft 12m Max Powdered 20 ft 6m Midway Urea 32 ft 10m Max The spreader unit can be fitted with t...

Страница 5: ...0 5 6 8 0 9 7 12 1 39 5 26 4 19 3 15 6 12 8 180 1 119 8 89 5 71 9 59 1 451 9 300 7 201 1 180 9 154 9 804 3 536 0 402 0 322 0 267 4 1232 3 819 9 616 0 491 2 410 4 1639 8 1092 9 819 9 654 8 546 1 1999 5...

Страница 6: ...the application rate required 2 Close the regulator disc using the toggle switch on the control box or the flow control handle 3 Take the machine to the work site 4 Just prior to the actual spreading...

Страница 7: ...slowly while spraying water inside the hopper 3 Open the regulator disc and spray the agitator and regulating plate 4 Spray all of the outside surfaces of the spreader MAINTENANCE AFTER THE INITIAL RU...

Страница 8: ......