Menu: DB Monitor
Displays the voltage and amperage of the
daughterboards attached to the motherboard,
as well as the amps for L1 and L2 (black and
white respectively) terminals.
Menu: DB Monitor
DB1
DB2
Volts 38.8V
None
Amps 0.000A
L1 0.000A
L2 0.000A
Menu: Event Codes
Displays the SmartHub’s Event Code log. You
can clear the log from this option. Navigate
to the Clear field using the Down arrow
, select Yes using the Input Dial
and
press the Down arrow
to activate.
Menu: Event Codes
Clear log: No
Last Code: 131, 005
01/12/12, 09:37:20
Menu: Decoder
Communications
Displays real-time communication data
between the TM and a decoder.
Menu: Decoder Comm.
Sent: Rd Flow Bd1
Resp: Ok
Total bad Resp: 000
Total Timeouts: 000
Clear Totals : No
Menu: Decoder
Diagnostics
This command allows the user to run
diagnostic tests that send messages to decoders
and modules. The faceplate will show the last
test performed at the TM. The tests include:
• communication (pictured)
• solenoid (pictured)
• LSM voltage
• LSM amps
• LSM version
• LSM Hardware Errors
• LSM Grp02 Info
• LSM Grp16 Info
• LSM Group Ping
• Group Volts
• Group Amps
• Group Errors
• Group Sta’s On
• LSM Grp Charge Fail
• Cable Resistance (pictured) *
• Decoder Output *
• Decoder Version *
• DBoard Output *
• DBoard Version *
Note
: Tests marked with an asterix (*)
are for GAC only.
Menu: Decoder Diag.
Communication
Brd 01, Sta 001
Press to start
34.78V 0.14A
Status: 03 DONE
Menu: Decoder Diag.
Solenoid
Brd 01, Sta 001
Press to start
Result: 00 Out1 OK
Status: 03 DONE
Menu: Decoder Diag.
Cable Resistance
Brd 01, Sta 001
Press to start
1.25V/0.31A = 4.1
Ω
Status: 03 DONE
Menu: Radio Tx Chars
This menu item transmits numerical sequences
to another radio for troubleshooting purposes.
35
Lynx® SmartHub Installation and User Guide