background image

SmartHub Settings

 Satellite Settings allows you to set SmartHub parameters such as Time, Date and Language. 

•  Use the Up or Down Arrows 

 to navigate through the menus.

•  Use the Left and Right Arrow 

 to advance to the next entry field on the same menu line.

•  Use the Input Dial 

 to select values when editing.

Command

Function

Comm Mode:

Use this menu item to select the SmartHub mode of  operation between Central, Local or Off  mode.

Hold All:

This command suspends satellite operation. Select the suspension duration from 

Today

02-30

 days, 

Permanent

 or 

None

. This does not affect manual starts from the front panel.

Hold Rain:

This command suspends satellite operation. Select the suspension duration from 

Today

02-30

 

days, 

Permanent

 or 

None

. When activated, Hold Rain will cancel any current watering, along with 

suspending operation. This does not affect manual starts from the front panel, nor does it affect 

stations defined as switches.

Reset Prg’s:

This command resets all programs by selecting Yes All. After selecting Yes All, press the Up or Down 

Arrows 

 to activate. There is a short countdown before the command executes during 

which the command can be cancelled.

Reset All Programss

to defaults

05

STOP to escape

All program settings will be erased after a successful reset.

Reset Sta’s: 

This command resets all station settings by selecting Yes. After selecting Yes, press the Up or Down 

Arrows 

 to activate. There is a short countdown before the command executes during 

which the command can be cancelled.

Reset All Stations

to defaults

05

STOP to escape

All station settings will be erased after a successful reset.

Reset Unit:

This command resets the SmartHub settings by selecting Yes. Select Yes using the Input Dial 

 and press the Up or Down Arrows 

 to activate.There is countdown during which 

the command can be cancelled before the SmartHub reboots. 

Reset All Defaults

10

STOP to escape

 

!

  Resetting the unit will erase all user-defined program data and configuration values in the 

SmartHub’s memory.

Power Mode:

This setting shows the power mode as “Switched” or “Continuous”. We recommend “Switched”. 

LSM System:

This setting sets the type of decoders attached to the SmartHub controller. Options: Yes or No.

Send OFFs:

This setting will send an extra OFF command when a station or irrigation program is stopped or ends. 

Options: Yes or No. We recommend No.

Enable Sta’s:

This setting resets all disabled stations with one execution. Select Yes All using the Input Dial 

 and press the Up or Down Arrows 

 to activate. Select No to cancel. Individual 

stations can be enabled/disabled by using the Disable function within the Station Settings menu.

Language:

Default language is English. Options are English, Spanish, French, and Italian.

28

Lynx® SmartHub Installation and User Guide

Содержание Lynx SmartHub

Страница 1: ...Lynx SmartHub for LSM GAC Installation and User Guide DEC and DAC Series...

Страница 2: ...unication Cable 18 Communicating with the SmartHub 19 Layout 1 Local 19 Layout 2 Wired Lynx 20 Layout 3 Wireless 20 Radio Communication FIU to SmartHub 21 Changing the Frequency of the Radio 22 Operat...

Страница 3: ...onduit of various diameters to enable power field ground and communication wiring to be routed into the pedestal for connection A mounting bolt positioner and basic mounting hardware components are in...

Страница 4: ...n from direct sunlight rain wind and snow as possible IMPORTANT Do not mount the controller where it is exposed to direct spray from the irrigation system Steps 1 Drill two pilot holes 6 15 25cm apart...

Страница 5: ...3 Strip the power cables and secure them to the terminal block Figure 3 Reference Table 1 for the appropriate type of power connection 4 Reinstall the power supply cover 5 Apply power to the controll...

Страница 6: ...r 6 Pour concrete into the formed foundation hole Press the mounting bolt positioner into the concrete until it is flush and level with the foundation surface and aligned with the conduit 7 Finish the...

Страница 7: ...lush with or below ground level and should be protected from damage using a valve box A 2 Measure the ground resistance per the instructions provided with the ground test instrument If reading is 10 o...

Страница 8: ...x SmartHub Installation and User Guide 8 2 4m 8 2 4m 8 2 4m 8 2 4m 8 2 4m No solenoid power or communication cables within this zone pedestal or gateway concrete pad grounding rod grounding plate Figu...

Страница 9: ...block Reference Table 1 and Figure 7 for the appropriate type of power connection 3 Reinstall the power supply cover 4 Apply power to the controller WARNING AC POWER WIRING MUST BE INSTALLED AND CONNE...

Страница 10: ...without conduit All field wiring splices must be accessible to facilitate troubleshooting and or service Steps 1 Route communication cable from the controller to the station module installation locat...

Страница 11: ...oubleshooting install wires with the same color code as the station wires Each station can activate up to two DC Latching Solenoids Out to additional modules Station Wires The Lynx SmartHub output boa...

Страница 12: ...oute communication cable from the controller to the station decoder module installation location The maximum wire length between the controller and the decoder module is 6 800 2072 m 2 Secure the comm...

Страница 13: ...on 3 s solenoid wires Station 4 Orange Wire Connect to one of Station 4 s solenoid wires Red Power Communication Wire Black Power Communication Wire Output Circuit 1 AC Solenoid Black Black Each stati...

Страница 14: ...ng listed in Table 2 below Table 2 Power Cable Circuit Rating Minimum KVA Recommended Minimum Spacing 0 3 6 inches 15 cm 3 10 12 inches 30 cm 10 20 24 inches 60 cm 20 50 36 inches 90 cm 50 100 48 inch...

Страница 15: ...d wire to the ground rod or plate s wire If the ground rod or plate is not pre wired use a 10 AWG bare copper wire 5 Drive a 5 8 by 8 17mm x 2 5m copper clad steel rod into well moistened soil not les...

Страница 16: ...Max B C 500 150m Max D 1000 300m Max Figure 10 For upgrades of existing systems we recommend adding one ground point Detail A at the end of each main communication line valve box black white DEC SG LI...

Страница 17: ...to the controller 2 Connect the cable wires to the Pressure Sensor Terminals labeled C in Figure 11 Red wire to the terminal black wire to the terminal 3 Place the controller s switch to ON Master Val...

Страница 18: ...of splicing device Using an appropriate splicing kit such as Scotchcast 82 A1 or equivalent is recommended Placing the cable splice in a small valve box for protection and accessibility is a good inst...

Страница 19: ...nd cabinet Smart Hubs are interchangeable with each other Layout 1 Local The SmartHub is attached to the Field Interface Unit by a Wireline The SmartHub typically resides in the office with the Lynx c...

Страница 20: ...1 2 3 4 MENU POWER AUTO LYNX SmartHub 1 SmartHub 2 Wired Lynx 1 2 3 The Wireline connection is limited to about 9 miles Layout 3 Wireless The Lynx SmartHub DEC RS 1000 DR digital radio and modem comm...

Страница 21: ...ton Figure 15 C 5 Click Start Operations button Figure 15 D Certain SmartHub information should be displayed on the screen Figure 16 If communication fails the software will display a fail message Fig...

Страница 22: ...eboot computer 3 Plug USB cable into a USB port and Serial port on radio Figure 18 4 Connect Phoenix power cable into 12V power supply Plug other end into DC IN port on radio Figure 19 5 Plug in 12V p...

Страница 23: ...nation selection is handled through the Personal Communications Industry Association PCIA 800 759 0300 and an application must be submitted to the FCC There is a PCIA fee and FCC license fee that must...

Страница 24: ...rams or other settings that impact watering Off Mode When placed in Off mode the SmartHub will not execute any watering operation whether it is program or manually initiated Any watering operation wil...

Страница 25: ...diagnostic information See page 33 10 Station Settings button allows you to modify station parameters Within this setting you can disable the station from any activity hold station watering for a spec...

Страница 26: ...will save any setting modifications and return the user to the Home display Home display examples The GW line displays the address of the controller In the example above the address of the SmartHub is...

Страница 27: ...ion page 31 Press the Stop button to cancel Pause Button The Pause button can be used to pause any running irrigation program or all irrigation activity Stop Button Use the Stop function to cancel all...

Страница 28: ...s This command resets all station settings by selecting Yes After selecting Yes press the Up or Down Arrows to activate There is a short countdown before the command executes during which the command...

Страница 29: ...nds Sta Delay This setting sets the station delay in seconds before any individual station activates This feature helps avoid water hammer Max Sim Sta This setting sets the maximum number of simultane...

Страница 30: ...he station to edit in this field Choose from Station 01 through the SmartHub maximum station count of 500 LSM or 250 GAC Allows the operator to set the percent adjust for the selected station if desir...

Страница 31: ...ne when plants trees or lawn need extra water A new sod lawn for example would benefit from a grow in program for a couple of weeks or month 5 For interval schedules it is necessary to define today s...

Страница 32: ...ub to implement changes SBF Lists are disabled when the controller is in Local Mode Manual Watering The Manual Watering functions are used for additional watering if the irrigation program is not suff...

Страница 33: ...rst value For our example select station 12 5 Press the Right Arrow to advance the cursor to the next entry field This entry field will indicate the runtime in hours and minutes HH MM Use the Input Di...

Страница 34: ...display the date and time of the last power down PD and last power up PU Press the Down arrow to scroll down the informations Menu PowerUp Detect DC 2 500 DB 1 1 0 0 PD 01 11 19 14 22 20 PU 01 12 19 0...

Страница 35: ...command allows the user to run diagnostic tests that send messages to decoders and modules The faceplate will show the last test performed at the TM The tests include communication pictured solenoid...

Страница 36: ...ot RSSI is Received Signal Strength Indication Menu Radio Settings Radio Power 040 Radio Addr 1181 RSSI Enable No Set Radio Dflts No Menu Radio Frequencies Displays the radio s send and receive freque...

Страница 37: ...they are on D1L1 0 24A D1L2 0 24A D2L1 0 24A D2L2 0 24A The display will also show the load currents by individual wires of a two wire communication line 1 open 0 2 open 0 The display will show the Ra...

Страница 38: ...ffected daughterboard s alarm LED blinks on and off Phase Current Imbalance Alarm D1L1 High Amp D2 A 0 500 D1L1 A 0 750 D2 A 0 500 Triggered when load current of one wire is 2x higher than the opposit...

Страница 39: ...butor or outside the United States call 951 688 9221 Neither Toro nor Toro Warranty Company is liable for indirect incidental or consequential damages in connection with the use of equipment including...

Страница 40: ...ion www toro com 1 877 345 8676 Form Number 373 0965 Rev C WARNING Cancer and Reproductive harm www P65Warnings ca gov For more information please visit www toro com CAProp65 Patent www ttcopats com 4...

Отзывы: