Station Settings allows you to set parameters specific to each station.
• Use the Up or Down Arrows
to navigate through the menus.
• Use the Left and Right Arrow Keys
to advance to the next entry field on the same menu line.
• Use the Input Dial
to select values when editing.
Command
Function
DB1
or
2
Select the daughterboard.
S01
Select the station you want to edit in this field. Choose from Station 01 through the gateway maximum
station count of 500 (per daughterboard).
Sched Today:
Total scheduled station runtime for the current irrigation day.
Water Today:
Total station runtime that has occurred for the current irrigation day.
Runtime resulting from a station that is manually activated via the output hardware switch will
not
be captured.
Water Yestr:
Total station runtime that occurred for the previous irrigation day.
Runtime resulting from a station that is manually activated via the output hardware switch will
not
be captured.
Disable:
Disable station operation by selecting
Yes
.
Resume station operation by s electing
No
.
S016 100% 1STSTLAWN
Decoder Addr: 38684
Dec Sta: 4 Board: 1
Disable: No
Hold:
Use this menu item to delay operation for this station. Select the hold duration from
01–30 days
,
Permanent
or
None
. This option is useful when a specific station needs to be deactivated without
affecting any of the programs. This does not affect manual starts from the front panel.
Capacitor
Voltage
Must be set to 15V only.
Dec Addrss:
Shows the 5-character address of the decoder module, is downloaded from Lynx.
Dec Offset:
Shows the ouput number (1,2,3, or 4), is downloaded from Lynx.