Day Change:
Use this menu item to set the “day change” time. The “day change” is the specified time that the
gateway will advance the date. The default day change is 12:00 am. Adjusting the day change time will
allow programs to start throughout the night on the same active day schedule. Programs with runtimes
beyond the day change time are allowed to finish.
GW Address:
Use this menu item to set the CSG (Central Gateway Group) address. Lynx uses this address to identify
different gateway groups.
Identify all gateways that can be grouped together and assign them with the same CSG address. When
Lynx sends out a command to that CSG address, all the gateways within that group will receive and
execute the command.
DB Address:
Use this menu item to set the gateway address. Each gateway must be given a unique
gateway address. Lynx uses this address to identify individual gateways when sending gateway specific
commands.
Max Sim Sta:
Use this menu item to set the maximum number of simultaneously operating stations. This threshold
will be applied to all programs and manual irrigation functions. Each program can then be set with a
lower limitation if necessary. This setting is set in Lynx and downloaded to the gateway.
Meas Units:
Use this menu item to set the gateway’s unit system between English (U.S. Standard) and Metric units.
Display Adj:
Use this menu item to adjust the contrast of the LCD screen. Use the Input Dial
to darken
or lighten the text display.