g191301
Figure 117
1.
Flange (pressure-filter
head)
4.
Quick-connect pin
2.
Flange (coupling adapter)
5.
Quick-connect coupler
(agitation hose)
3.
Flange clamp
6.
Quick-connect fitting
(agitation valve manifold)
2.
Loosely secure the agitation-valve manifold to
the agitation-bypass valve, pressure filter head,
and coupling adapter (
) with the 3
flange clamps that you removed in
the Agitation-Manifold Valve (page 76)
.
3.
Assemble the agitation-valve manifold to the
valve support with the 2 flange-head bolt (1/4 x
3/4 inch) and flange locknut (1/4 inch) that you
removed in
Removing the Agitation-Manifold
.
4.
Torque the flange-head bolts and flange locknuts
to 1978 to 2542 N∙cm (175 to 225 in-lb).
5.
Tighten the 3 flange clamps by hand (
6.
Assemble the quick-connect coupler of the
agitation hose onto the quick-connect fitting
of the agitation-valve manifold with the
quick-connect pin (
7.
If you loosened the mounting hardware for the
pressure-filter head, tighten the nut and bolt to
1978 to 2542 N∙cm (175 to 225 in-lb).
Installing the Valve Actuator
1.
Align the actuator to the manifold valve (
2.
Secure the actuator and valve with the retainer
that you removed in step
of
Valve Actuator (page 76)
.
82
Содержание 41393
Страница 88: ...Schematics g034336 Sprayer System Schematic Rev DWG 131 9559 Rev A 88...
Страница 89: ...Notes...
Страница 90: ...Notes...