![Toro 30809 Groundsmaster 3500-G Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/toro/30809-groundsmaster-3500-g/30809-groundsmaster-3500-g_operators-manual_1133263041.webp)
maximum force required to operate the throttle lever
should not exceed 27 N-m (20 ft-lb).
Cooling System
Maintenance
Cleaning the Engine Cooling
System
Service Interval:
Before each use or daily
Every 2 years
Remove debris from the radiator/oil cooler daily. Clean the
radiator/oil more frequently in dirty conditions.
1.
Turn the engine off and allow it to cool.
2.
Raise the hood.
3.
Remove debris from the engine.
4.
Clean both sides of the radiator/oil cooler area
thoroughly with water or compressed air (
).
Figure 54
1.
Radiator/oil cooler
5.
Close the hood.