background image

Figure 1

1.

Right-hand wheel shroud

4.

Screen panel

2.

Nut (2)

5.

Screws

3.

Bolt and washer (2)

3.

Remove and retain the shroud.

Note:

If a Manual Blade (Model 08714) is installed on

the machine, remove the right blade-mounting bracket
before installing the lift arm assembly.

4.

Remove the 2 screws, 2 bolts, 2 washers and 2 nuts that
secure the screen panel to the frame (Figure 1).

Note:

Remove and discard the screen panel, but retain

the washers and nuts.

5.

Install the mounting bracket of the scarifier lift-handle
assembly to the right footrest tubes with 2 bolts (1/2
x 3-1/4 inch) and thin locknuts (1/2 inch), as shown
in Figure 2.

Figure 2

1.

Bolt (1/2 x 3-1/4 inch)

4.

Thin locknuts (1/2 inch)

2.

Mounting bracket

5.

Footrest tube

3.

Scarifier lift-handle
assembly

6.

Hydraulic line

Note:

Ensure that the bolt heads are positioned to the

outside and that the thin locknuts are used.

Important:

There are both thick and thin locknuts

in the loose parts. Use the thin locknuts for this

step. If you use the thick ones, they will not lock
on and will eventually fall off.

Note:

The handle assembly is installed through the

bottom of the traction unit by guiding the handle up
through the opening made by removing the screen
panel.

Note:

Do not disassemble the handle assembly to

install it into the traction unit.

6.

Insert the detent plate onto the scarifier lift handle.

Note:

The handle should pass between the detent

plate and the handle guide (Figure 3).

8

G019398

Figure 3

1.

Locknut (5/16 inch) (2)

5.

Scarifier lift handle

2.

Right rear frame tube

6.

Knob

3.

Detent plate

7.

Washer (2)

4.

Handle guide

8.

Bolt (5/16 x 2-1/4 inch) (2)

7.

Install the detent plate to the back of the right rear
vertical frame tube with 2 bolts (5/16 x 2-1/4 inch), 2
washers, and 2 locknuts (5/16 inch) (Use the washers
and locknuts removed in step 4). Position the parts as
shown in Figure 3.)

8.

Thread the knob onto the lift handle (Figure 3).

9.

Ensure that the lift handle moves the full range of
motion through the detent plate and that it locks into
place at each detent location.

Note:

If the lift handle is too loose or too tight,

tighten or loosen the locknuts on the handle lift pivot
(Figure 4).

3

Содержание 08731

Страница 1: ...hes 2 Thin locknut 1 2 inch 2 Detent plate 1 2 Knob 1 Install the scarifier lift handle assembly Pivot tube 1 Extension spring 1 Spring rod 1 Pivot tube bracket 2 Bolt 3 8 x 3 inches 4 Locknut 3 8 inc...

Страница 2: ...quired Procedure Note If you will be installing the spring tine toolbar install the pivot tube brackets supplied with the spring tine toolbar instead of the ones supplied with this attachment Refer to...

Страница 3: ...p If you use the thick ones they will not lock on and will eventually fall off Note The handle assembly is installed through the bottom of the traction unit by guiding the handle up through the openin...

Страница 4: ...on 1 Connect the extension spring to one of the spring levers on the pivot tube and to the spring rod Figure 5 Figure 5 1 Locknut 3 8 inch 5 Extension spring 2 Pivot tube bracket 6 Spring rod 3 Bolt 3...

Страница 5: ...secure it with a locknut 1 2 inch Figure 7 Note You can move the pivot tube up or down in its brackets to gain clearance for mounting the adjustable rod 4 Move the lift handle all the way downward to...

Страница 6: ...h a bolt 5 16 x 1 inch and a locknut 5 16 inch Note The saddle stud should point inward Figure 10 Note Position the saddles as shown in Figure 10 Figure 10 1 Bolt 5 16 x 1 inch 3 Lift arm 2 Saddle 4 L...

Страница 7: ...nstalling the Toolbar Lift Pedal Parts needed for this procedure 1 Lever assembly 1 Bolt 5 16 x 2 inches 3 Locknut 5 16 inch 1 Pivot tab 1 Toolbar link 1 Carriage bolt 3 8 x 1 1 4 inches 1 Spacer 1 Wa...

Страница 8: ...the pedal lever assembly and secure it with a retaining ring Figure 15 Figure 15 1 Toolbar link 4 Retaining ring 2 Pedal lever assembly 5 Washer 7 8 inch 3 Lever assembly 4 Install the post on the ot...

Страница 9: ...Tension and the Adjustable Rod Assembly No Parts Required Procedure 1 Position the lift handle in the top detent position 2 Measure the distance between the traction unit frame and the pivot tube as...

Страница 10: ...e notch in the lift arm Figure 17 and Figure 21 Important The eccentric bolt will not rotate 360 degrees When it stops do not attempt to force it further or you will damage it Instead rotate it back t...

Страница 11: ...to the left raise it and then slide it to the right into the desired detent position To raise and lock the toolbar into the transport position move the lift handle to the highest position and press t...

Страница 12: ...2 Spring sleeve casting Use the following table and figure as a guide for adjusting the downward toolbar pressure Figure 24 Spring Force Chart Dimension inches Force pounds 3 00 238 2 88 335 2 75 430...

Страница 13: ...embly to the scarifier mount assembly refer to the Parts Catalog for parts illustration Tighten the nut until it is snug and then back them off slightly to allow for free rotation 1 The eccentric bolt...

Страница 14: ...Notes 14...

Страница 15: ...Notes 15...

Страница 16: ...ed to damage to seats due to wear or abrasion worn painted surfaces scratched decals or windows etc Parts Parts scheduled for replacement as required maintenance are warranted for the period of time u...

Отзывы: