10
9. Accessories
I
tem
Part No.
Usage
12V 55Ah maintenance batteries (2 required)
99562
Replacement batteries
Spray system kit incl. mounting bracket & tubing
05-4156-000
Spray cleaning attachment
10. Fault diagnosis
The following simple checks may be performed by the operator:
Trouble
Reason
Remedy
No lights illuminated on charger
module
Power failure
Check the mains fuse, the power supply cord
and plug
Yellow LED flashing
Unsuitable battery
Battery not connected
Connect battery
Contact service agent
Only Red LED on charger mod-
ule is illuminated
Charger not connected correctly Battery is faulty
Charging time out
Contact service agent
Machine not working
Switch interlock incorrectly
operated
Charging time out
Machine not working
Switch interlock incorrectly operated
Contact service agent
Machine wobbles or vibrates
excessively
Pad worn or damaged
Pad not centred on drive disc
Pad dirty
Incorrect pad selection
Install new pad
Place pad in correct position
Clean the pad
Contact pad supplier
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.