PREPARE THE MACHINE FOR 

OPERATION

To attach the drive block or brush or other attachment, be sure 

the handle is “locked” in the upright position 

(See picture #1)

Lay the floor machine on its back with the handle lying on the 

floor,  this exposes the driving plate on the underside of the floor 

machine. Holding the drive block, brush or attachment in both 

hands and straddling the motor with your back to the handlebox, 

bend over and fit the three slots of the clutch plate (build into the 

back of the brush) over the three lugs of the driving plate. Turn 

the drive block, brush or attachment counter-clockwise as far as 

it will go until it is seated in the ready-to-use position. 

(See pic-

ture #2)

  

CAUTION

: This is the only proper way to install a drive 

block, brush or attachment. NEVER put a drive block, brush or 

attachment on the machine by placing it on the floor and mov-

ing the running machine over it, or by placing the machine over 

the block or attachment and then starting the motor.  Return the 

floor machine to upright position and adjust handle to operating 

position. Recommended handle position is close to the waist with 

arms extended down.  Lock the cam release lever into position.

NOTE

The hardened steel cam release lever does not require 

extreme tightening to effectively hold the handle in position. Over-

tightening will shorten the functional life of the lever. 

To remove 

drive block, brush or attachment:

 Lay the floor machine on it’s 

back again and disengage clutch plate slots from driving plate 

lugs by turning clockwise.

HOW TO OPERATE THE MACHINE

First install the pad driver and pad, brush or other attachments to 

be used.  Plug the machine in as directed and lower the handle 

to the desired operating height and lock in place using the cam 

lever handle. Push the safety switch forward 

(see picture #3)

 

and squeeze the switch triggers beneath the handle grips.   This 

activates the motor and starts the block, brush or attachment in 

operation.  Each time you release the triggers the safety switch 

will reset.  You will need to follow the direction above to restart 

the machine. 

CAUTION

When leaving the machine unattended, 

disconnect the wall plug and return the handle to the “locked” 

upright position to prevent accidental starting. 

TO GUIDE YOUR FLOOR MACHINE

To Right: raise handle slightly. The higher the handle is lifted, 

the faster the machine will move to the right.  To Left: to change 

direction, lower the handle until the machine travels to the left. 

The more the handle is lowered, the faster the movement to the 

left.

TO INSTALL THE OPTIONAL SOLUTION 

TANK

Mount the solution tank to the front of the handle and attach with 

mounting brackets and knobs. Position the solution tank control 

handle horizontally and below the switch lever of the machine 

and adjacent to the right handle grip.  Remove the plug from the 

motor housing and insert the (long) extension tube adaptor and 

secure at bottom of machine with the retainer. The solution tank 

should be used only with a showerfeed drive block or brush.

TRANSPORTING THE MACHINE

Place the handle in the upright position. Lock the handle cam 

release lever. Tip the machine back and transport on the wheels.

MAINTENANCE 

Once a month remove the motor cover and vacuum out any 

dust or debris which has accumulated on the motor.  Replace 

the motor cover by setting it over the holes in the housing and 

replace all of the screws.  Check and maintain the tightness of all 

the fasteners.

WARNING

: Do not over-tighten the switch housing screws.

Keep the machine clean especially at the handle tube and collar 

so the handle tube will move freely through the collar.  Inspect 

the cord for cuts, gashes, or loose prongs; replace as needed.

Disassembly of this motor voids the warranty. Improper disas-

sembly and assembly of this motor can permanently damage the 

field or rotor.

Picture #1

Picture #2

Picture #3

Switch 

Trigger

Safety 

Switch

Содержание 97562

Страница 1: ...MS FAX 817 551 0719 WWW TORNADOVAC COM Operations Maintenance Manual For Commercial Use Only Models P Series 17 and 20 MODEL NO 97562 115v 97563 230v 97564 115v 97565 230v 97598 115v Bi Speed 97599 115v Bi Speed Form No L 9703MAD 02 17 Tornado Industries LLC All rights reserved ...

Страница 2: ...e warranty Terms subject to change without notice 1 Except all Windshears Blowers Storm TV2SS Side and Downdraft Insulation Blowers CV 30 CV 38 CK14 1 PRO CK 14 2 PRO SWM 31 9 CK LW13 1 CK LW 13 1 ROAM CV 38 48 Dual PV6 PV10 PV6 ROAM Wall Mount Vacuum and all chargers are warranted for 1 one year for both parts and labor 2 All non wear item parts purchased after warranty expiration are warranted f...

Страница 3: ...NOTES 3 ...

Страница 4: ..._____ TABLE OF CONTENTS ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE IMPORTANT SAFEGUARDS 5 APPLICATIONS 5 MAINTENANCE 6 TROUBLESHOOTING 7 This instruction book covers MODEL NO 97562 97564 97563 97565 97598 97599 VOLTS 115 115 220 220 115 115 SERIES F F F F F F ...

Страница 5: ...and loose cloth ing away from the rotating pad WARNING Maintenance and repairs must be done by autho rized personnel only WARNING Keep all fasteners tight Keep adjustments according to specifications WARNING Keep the electrical parts of the machine dry For storage keep the machine in a building WARNING Always use a three wire electrical system connected to the electrical ground For maximum protect...

Страница 6: ...h triggers beneath the handle grips This activates the motor and starts the block brush or attachment in operation Each time you release the triggers the safety switch will reset You will need to follow the direction above to restart the machine CAUTION When leaving the machine unattended disconnect the wall plug and return the handle to the locked upright position to prevent accidental starting T...

Страница 7: ... replaced Replacement of the carbon brushes should only be done by a qualified service technician TROUBLESHOOTING Machine does not run The circuit breaker has tripped Allow the circuit breaker 2 min utes to cool before resetting Plug is broken or has loose con tact Replace Prevent circuit overload Check the pad and change it if it is rough or dirty Spray buffing or spray cleaning is not a substitu...

Страница 8: ...rnado cleaning and maintenance equipment In square feet meters Total Hard Floor Area Total Carpeted Area Square feet square meters o Contacted by local dealer o Previous experience with Tornado products o Reputation Recommendation o Advertising o Direct mail o Internet o Other o 0 10 000 0 930 o 10 50 000 930 4 650 o 50 250 000 4 650 23 250 o Over 250 000 over 23 260 o 0 10 000 0 930 o 10 50 000 9...

Страница 9: ...gs and Cautions Before Using EQUIPMENT These guidelines are presented for your protection and convenience Please read them carefully since a failure to heed these precautions could result in discomfort or injury When using an electrical appliance basic safety precau tions should always be followed 2010 Tacony Inc All rights reserved ...

Страница 10: ...s à changement sans préavis 1 Sauf toutes les ventilateur sécheurs de côté et descendant les ventilateurs d isolation TV2 SS CV 30 CV 38 CK14 1 PRO CK14 2 PRO SWM 31 9 CK LW 13 1 CK LW 13 1 ROAM Double CV 38 48 PV6 PV10 PV6 ROAM Wall Mount de Windshear toutes les balayeuses brosses les aspirateurs à traineau sec et tous les chargeurs sont garantis pendant 1 un an pour les pièces et le travail 2 To...

Страница 11: ...REMARQUES 2 ...

Страница 12: ... F F Reportez le numéro de série de votre machine ici ________________________________ Ce manuel d instructions illustré comprend TOUTES LES CARACTÉRISTIQUES TECHNIQUES SONT SUJETTES À MODIFICATION SANS PRÉAVIS TABLES DES MATIÈRES PRÉCAUTIONS IMPORTANTES 4 APPLICATIONS 4 ENTRETIEN 5 DÉPANNAGE 5 3 ...

Страница 13: ...if ATTENTION La maintenance et les réparations doivent être effectuées par du personnel autorisé seulement ATTENTION Veillez au verrouillage adéquat des fixations Maintenez les réglages conformes aux spécifications ATTENTION Assurez vous que les pièces électriques de la machine sont toujours sèches Pour le rangement conservez la machine à l intérieur ATTENTION Utilisez toujours un système électriq...

Страница 14: ...auteur de fonctionnement souhaitée puis verrouillez la à l aide du levier à came Poussez l interrupteur de sécurité vers l avant voir Image no 3 et pressez les gâchettes sous les poignées Cela active le moteur et démarre le bloc la brosse ou l accessoire utilisé Chaque fois que vous relâchez les gâchettes l interrupteur de sécurité se réinitialise Vous devrez suivre les indications ci dessus pour ...

Страница 15: ...les remplacer Le remplacement des balais de charbon doit seulement être effectué par un technicien de service qualifié DÉPANNAGE La machine ne fonctionne pas Le disjoncteur s est déclenché Laissez le disjoncteur refroidir pendant 2 minutes avant de le réinitialiser La fiche est cassée ou présente un faux contact Remplacez la Prévenez la surcharge du circuit Vérifiez le tampon et remplacez le s il ...

Страница 16: ...9 Hôpital 17 Gouvernement des É U 2 Magasin de détail 10 Maison de retraite 18 Autre gouvernement 3 Restaurant 11 Institution religieuse 19 Service automobile 4 Immeuble de bureaux 12 Entrepôt 20 Aéroport 5 Nettoyage contractuel 13 Aéroport 21 À but non lucratif 6 Industrie légère 14 Appartement Condo 22 Autre spécifier 7 Industrie lourde 15 Entrepôt _________________ 8 Collège Université 16 Super...

Страница 17: ...VERTISSEMENTS AVANT D UTILISER L APPAREIL Ces directives sont présentées pour votre protection et votre confort Veuillez les lire attentivement car ne pas tenir compte de ces précautions pourrait générer une gêne ou occasionner des blessures Lorsque vous utilisez un appareil électrique vous devez toujours respecter certaines précautions de sécurité de base 2010 Tacony Inc Tous droits réservés ...

Страница 18: ...el fabricante de las baterías en base a un año prorrateado Términos sujetos a cambios sin previo aviso 1 Con excepción de los Ventiladores Secadores Windshear de tiro lateral y descendente Ventiladores de Aislamien to CV 30 CV 38 CK14 1 PRO CK 14 2 PRO SWM31 9 CK LW 13 1 CK LW 13 1 ROAM CV 38 48 Dual PV6 PV10 PV6 ROAM Wall Mount todas las Barredoras Aspiradoras en Seco y todos los cargadores tiene...

Страница 19: ...NOTAS 2 ...

Страница 20: ... F F Escriba aquí el número de serie de su unidad ________________________________ Este manual de instrucciones incluye TODAS LAS ESPECIFICACIONES ESTÁN SUJETAS A CAMBIOS SIN PREVIO AVISO ÍNDICE PRECAUCIONES IMPORTANTES 4 APLICACIONES 4 MANTENIMIENTO 5 IDENTIFICACIÓN Y RESOLUCIÓN DE PROBLEMAS 6 3 ...

Страница 21: ...ADVERTENCIA Mantenga todas las abrazaderas bien ajustadas Mantenga los ajustes de acuerdo con las especificaciones ADVERTENCIA Mantenga secas las piezas eléctricas de la unidad Para el almacenamiento mantenga la unidad dentro de un edificio ADVERTENCIA Siempre use un sistema eléctrico de tres hilos para la conexión eléctrica a tierra Para una máxima protección contra descargas eléctricas utilice u...

Страница 22: ... la palanca de leva Empuje el interruptor de seguridad hacia adelante vea la fig 3 y apriete los gatillos interruptores debajo de las asas Esto enciende el motor y activa el bloque el cepillo o el accesorio en funcionamiento Cada vez que suelte los gatillos se reiniciará el interruptor de seguridad Siga la indicación anterior para reiniciar la unidad PRECAUCIÓN Cuando deje la unidad sin supervisió...

Страница 23: ...ás allá de la ventana del soporte deben reemplazarse Solo un técnico de mantenimiento calificado debe reemplazar las escobillas de carbón IDENTIFICACIÓN Y RESOLUCIÓN DE PROBLEMAS La unidad no funciona El disyuntor se ha activado Deje enfriar el disyuntor durante 2 minutos antes de reiniciar El enchufe está roto o tiene un contacto flojo Cámbielo Evite la sobrecarga del circuito Revise la almohadil...

Страница 24: ...a minorista 10 Residencia geriátrica 18 Otras dependencias del gobierno 3 Restaurant 11 Institución religiosa 19 Auto servicio 4 Edificio de oficinas 12 Aeropuerto 20 Aeropuerto 5 Servicio de limpieza 13 Depósito 21 ONG 6 Fabricación liviana 14 Departamento Condominio 22 Otra especificar 7 Fabricación pesada 15 Depósito ______________ 8 Facultad Universidad 16 Supermercado ______________ Cómo cono...

Страница 25: ...O LEA TODAS LAS INSTRUCCIONES ADVERTENCIAS Y PRECAUCIONES Estas instrucciones se ofrecen para su protección y conveniencia Léalas detenidamente ya que su incumplimiento podría causar problemas o lesiones Cuando se usa un aparato eléctrico siempre deben seguirse precauciones básicas de seguridad 2010 Tacony Inc Todos los derechos reservados ...

Отзывы: