- 41 -
Check if the power switches and buttons work well; check if all the indicators light up
normally after start-up; if any, please replace it in time. Enter the software to check if all the
basic functions work well. In case of any software anomalies, please contact our company or
authorized dealers to get the latest version for software upgrade.
5) Performance test and calibration
The quality of medical equipment shall rely not only on the qualified acceptance
procedures, but also on the effective measurement monitoring during the use. Since the
equipment will depreciate during the use, whose performance indicators and technical
parameters will vary along with frequency of use and working conditions, operators shall
check it regularly with measurement techniques for the change of performance, and carry out
the calibration and maintenance of unqualified equipment timely.
This equipment shall be checked according to JJG 1143-2017 code, and can be used
only after passing the inspection.
Verification cycle, in general, shall be no longer than 1 year.
If it is confirmed to be unqualified, please contact our company or authorized dealers.
6
Precautions
1) Never use this equipment in the flammable, explosive, hot and dusty environment. It shall
be used indoors.
2) Keep the floor clean and dry.
3) Before use, please check if all the cords are connected correctly and solidly, and make sure
that the equipment is well grounded.
4) Please use the fuse tubes of models and rated values meeting the specifications of this
product. The specification of the configured fuse tube is T2AL250V. Before replacing the
fuse tube, please cut off the power supply.
5) Adopt the power cords specialized for this equipment.
6) Never touch the surface of optical elements with hands or hard objects.
7) Never put fingers, hair or other body parts at the moveable parts of equipment, or otherwise,
you may be injured.
8) The equipment shall be installed on the flat ground, which can prevent the equipment from
falling down.
9) When the equipment is idle, it's necessary to disconnect the power supply and cover it with
dust guard.
10) Other medical devices and equipment that are required to install in the same environment
for use shall follow the same electromagnetic compatibility principles. Those failing to follow
electromagnetic compatibility principles or with poor electromagnetic compatibility shall be
located at the place at least 3m away from this equipment and powered by different power
cords.
11) In case of any fault, please contact our company or the authorized dealers.
Содержание Kestrel 3100m
Страница 1: ...Kestrel 3100m Fundus Camera Technical and Operation Manual Shanghai Topview Industry Co Ltd...
Страница 4: ......
Страница 11: ...7 2 3 Division of function modules...
Страница 12: ...8...
Страница 13: ...9...
Страница 21: ...17 3 3 Image acquisition module 1 Image monitoring 2 Fundus alignment Manual and auto...
Страница 35: ...31...