Kestrel 3100m

Fundus Camera

Technical and Operation Manual

Shanghai Topview Industry Co. Ltd.

Содержание Kestrel 3100m

Страница 1: ...Kestrel 3100m Fundus Camera Technical and Operation Manual Shanghai Topview Industry Co Ltd...

Страница 2: ...pment Please do not place the parts of the equipment on the ground Do not plunge the plug in the process of equipment operation The AC power and equipment must be disconnected when cleaning up the equ...

Страница 3: ...ructure diagram 6 2 3 Division of function modules 7 2 4 Topology of hardware equipment 10 2 5 Names of the product parts 11 2 6 Description of product parts 12 3 Basic operation 13 3 1 Equipment star...

Страница 4: ......

Страница 5: ...cations 1 It should be used with caution in patients with keratopathy such as corneal edema and corneal scar 2 It should be forbidden for patients with severe keratopathy such as evident cornea thinni...

Страница 6: ...ition 4 View angle Field angle is 50 5 Compensation range for ametropia 20D 6 Image resolution 3264 2488 pixel 7 Acquisition pixel 8 million 8 Light source for observation Color rendering index Ra 85...

Страница 7: ...her with flammable anesthetizing gas mixed with air or with nitrous oxide Do not use it together with the flammable anesthetizing gas mixed with air or nitrous oxide 5 Classification by operating mode...

Страница 8: ...indows 8 1 64 bits serves as the system software without the need for additional support software or application software 1 11 Device installation Remove the packing according to the following picture...

Страница 9: ...th an area being 6 inches 8 inches about 1 8m 2 4m In order to prevent heat build up effect that could damage equipment it shall be installed in the well ventilated room with the equipment s ventilati...

Страница 10: ...n Medical Equipment Ltd Supplier address 1 10 Floor 9th of building 4 Group 2N of 2nd Project Fulicheng Zhihuiguoji Shapingba District 401331 Chongqing CHINA 2 Product structure 2 1 Structural composi...

Страница 11: ...7 2 3 Division of function modules...

Страница 12: ...8...

Страница 13: ...9...

Страница 14: ...sed to update software save data and print reports In case of any fault in the touch screen data shall still be input via connecting USB2 0 supportive keyboard and mouse DVI interface DVI D format int...

Страница 15: ...11 2 5 Names of the product parts 1 Objective lens 2 Forehead rest forehead cushion 3 Chin rest 4 Base foundation 5 Touch screen 6 Power button 7 Computer switch 8 USB Front View 1 Side View 2...

Страница 16: ...hed to the forehead rest Connect the external device Print and output data Head Head consists of main working parts of the equipment Touch screen Touch screen serves as the interactive interface and m...

Страница 17: ...ase of any fault of LCD touch screen Network interface Disabled currently reserved interface for software upgrade in the future RJ 45 Ethernet interface following IEEE802 3 Standards The power cord in...

Страница 18: ...the cursor at Patient Information list select Work List to enter the work list interface and then click Query to get the work list and click Load to load the data of the selected work list into the Pa...

Страница 19: ...medical records the operator can search it via history window Click Latest Record at the upper part of the interface click Search via inputting the patient s first name last name or ID or creation da...

Страница 20: ...onths Export data and images at specific month or data 5 Data export Export data under Data Maintenance interface Connect the external USB storage select specified month and date and then click Export...

Страница 21: ...17 3 3 Image acquisition module 1 Image monitoring 2 Fundus alignment Manual and auto...

Страница 22: ...to icons on the acquisition function interface Select manual mode to take pictures Up 3D movement system One click shooting Down 3D movement system Eye position Right Left 3D movement system Eye posi...

Страница 23: ...tomatically Auto binocular filming mode Automatically film one eye and then the other one Turn on off the outer fixation lamp Inner fixation lamp Prompt that pupils shall be between two lines Photo vi...

Страница 24: ...art with cotton balls immersed in medical alcohol or use disposable chin rest paper Have the patient sit down and adjust the height of the chair or worktable to have patient s chin and forehead closel...

Страница 25: ...tion and click One click Shooting again to complete the image acquisition of both eyes 6 Parameter setting 1 System setting Modify all the parameters of the system 2 DICOM3 setting Configurations rela...

Страница 26: ...22 3 Set the LAN anonymous sharing Windows Configurations of anonymous address sharing of local area network LAN...

Страница 27: ...output Modify the options on the connected printer and select the corresponding printer 5 FTP Transmit images to the shared folders simultaneously via LAN and complete the real time analysis by the t...

Страница 28: ...24 6 Case Establish the case database and achieve the management on viewing adding replacing or removing cases 7 Inner fixation parameters setting...

Страница 29: ...or single clicking the targeted image click the image viewer button to view images by rolling the mouse wheel or touch screen gestures to zoom in out 2 Multi selection mode Under the multi selection m...

Страница 30: ...selection mode tick one image click Delete to remove the ticked image 6 Diagnosis information Select click to select the record list double click the content in the list fill in the diagnosis informat...

Страница 31: ...tion manually 7 Function selection Upload DICOM3 export to USB storage and image mosaic 2 Comparison of two images 1 It is at the image management interface Select the function of comparison of two im...

Страница 32: ...ages of the same part for comparing and observing the locations of lesions Select and click to the lock icon to zoom in and out the two images to the same scale by rolling the mouse wheel Select and c...

Страница 33: ...osaic 1 Enter into the image management interface click Multi selection Mode button at the bottom to check the image mosaic among the function options 2 Click Function button to carry out image mosaic...

Страница 34: ...on different directions to acquire fundus images of different eye positions Number of image mosaic Maximum 9 images for each time Select images as needed and then start the image mosaic Positioning Cl...

Страница 35: ...31...

Страница 36: ...e effect as needed Gamma adjustment brightness adjustment contrast adjustment RGB gain adjustment After the image effect intensification and adjustment is completed click Save to generate new images 2...

Страница 37: ...a Remove Select and move Annotation tool Distance tool CDR tool Polygon area calculation tool Adjustment tool Display the calculation result Refresh restore the default size of images Hide the calcula...

Страница 38: ...nt button to print reports as needed Dual image template A5 Use A5 paper to print 2 images Print with A4 Print and export the report on A4 paper Print with A5 Print and export the report on A5 paper P...

Страница 39: ...lick About button at the right bottom to check the information about software version About the version Detailed information of the product is as below Storage switch Click Storage Switch button at th...

Страница 40: ...ent packing operation Packing Click Packing button at the right bottom to pack at the minimized form automatically 2 After entering the homepage of the system operation interface click Close button at...

Страница 41: ...are is not started the first step Insert U disk first Step 2 Turn on the power switch and start the equipment Step 3 Run software detection function and identify U disk with software upgrade package w...

Страница 42: ...daily maintenance and its daily maintenance is only about cleaning the parts exposed to the human body Before cleaning and maintenance please disconnect the power supply of the equipment 4 1 Cleaning...

Страница 43: ...ean the optical devices only when they are dirty Notes Since optical devices are easily damageable they cannot be wiped frequently and the operators shall try to avoid contacting the optical surface d...

Страница 44: ...t be removed completely please dip some water to wet the soft cloth Other external surface Other external surface of equipment can be cleaned with soft lint free cloth wetted with little water Cleanin...

Страница 45: ...uipment in the flammable explosive hot and dusty environment It shall be used indoors 2 Keep the floor clean and dry 3 Before use please check if all the cords are connected correctly and solidly and...

Страница 46: ...nt to put the chin on the chin rest and lean the head on the forehead rest 3 Require the patient to focus on the fixation lamp 4 Require the patient to blink a few times before continuing to measure N...

Страница 47: ...pment the replaced components or other wastes should be properly disposed according to local laws and regulations and should not be discarded arbitrarily The equipment should be recycled in accordance...

Страница 48: ...of 3 0m Parenthesis USB cable Shielded 3 0m at most Not attached HDMI cable Shielded 2 7m at most Not attached 4 Failure to adopt the specified accessories energy converters and cables may result in t...

Страница 49: ...or hospital environment Surge impact GB T 17626 5 1kV line to ground 2kV line to ground 1kV line to ground 2kV line to ground The network power supply shall be of typical quality applicable to commerc...

Страница 50: ...equipment and mobile radio frequency communication equipment their distance towards any part of Kestrel 3100m including cables shall be larger than the recommended distance calculated according to the...

Страница 51: ...Hz 80 MHz d 1 2 80 MHz 800 MHz d 1 2 800 MHz 2 5 GHz d 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For the maximum rated output of transmitter not listed in th...

Страница 52: ...mine if the power of button batteries is run out Measure it with the voltage function of the multimeter and when the power is lower than 2V the equipment will fail to work 3 Confirm the cathode and an...

Отзывы: