Set Time

Programming

Weekday        Wake 

          6 a.m.  

       70° F (21° C)  

 75° F (24° C)          System Average 

       Leave 

          8 a.m. 

       62° F (17° C)  

 83° F (28° C)          System Average 

       Return 

          6 p.m. 

       70° F (21° C)  

 75° F (24° C)          System Average 

       Sleep 

          10 p.m.         62° F (17° C)  

 78° F (26° C)          System Average 

Factory Default Program

Saturday        Wake 

          8 a.m. 

       70° F (21° C)  

 75° F (24° C)          System Average 

       Leave 

          10 a.m.         62° F (17° C)  

 83° F (28° C)          System Average 

       Return 

          6 p.m. 

       70° F (21° C)  

 75° F (24° C)          System Average 

       Sleep 

          11 p.m.         62° F (17° C)  

 78° F (26° C)          System Average 

Sunday

       Wake 

          8 a.m. 

       70° F (21° C)  

 75° F (24° C)          System Average 

       Leave 

          10 a.m.         62° F (17° C)  

  83° F (28° C)          System Average

       Return 

          6 p.m. 

       70° F (21° C)  

  75° F (24° C)          System Average 

       Sleep 

          11 p.m.         62° F (17° C)  

  78° F (26° C)          System Average 

Day of the 

Week

Setpoint 

Temperature (Cool)

Zone 

(If R251W is connected)

Setpoint 

Temperature (Heat)

Time

Events

Follow the steps below to set the day of the week and current time:

Press 

MENU

Press 

SET TIME

Day of the week will be flashing.  Use the            or            key to select the current 

day of the week.

Press 

NEXT STEP

The current hour is flashing.  Use the            or            key to select the current hour.  

When using 12-hour time, make sure the correct a.m. or p.m. choice is selected.

Press 

NEXT STEP

Minutes are now flashing.  Use the            or            key to select current minutes.

Press 

DONE

 when completed

1.

2.

3.

4.

5.

6.

7.

8.

All programmable Pro1 thermostats are shipped with an energy saving pre-program.  You can customize 
this default program by following the Set Program Schedule.

Your thermostat can be programmed to have each day of the week programmed uniquely (7days), all the 
weekdays the same with a separate program for Saturday and a separate program for Sunday (5+1+1), 
or nonprogrammable.  There are four time periods for each day (

WAKE

LEAVE

RETURN

SLEEP

).

This thermostat has a programmable fan feature, which allows you to run the fan continuously during any 
time period.

Содержание truecomfort iii

Страница 1: ...with Battery Backup If using remote sensors the thermostat must be hardwired Power Type 1 Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Multi...

Страница 2: ...hermostat becomes inoperable The batteries are located on the back of the thermostat Clean Display Pressing CLEAN DISPLAY will allow 30 seconds to clean the display The keys will be inoperable during...

Страница 3: ...are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be conceal...

Страница 4: ...NOT weatherproof Base Module Basement Installation 4 PRO1 Tip Wireless Range Range between the T955W and the base module is up to 100 feet with no obstructions and up to 50 feet in standard residenti...

Страница 5: ...rproof Base Module Attic Installation 5 PRO1 Tip When performing an attic installation instead of placing the base module in the attic locate the closet nearest to the air conditioning unit Then mount...

Страница 6: ...ose of it properly Your local waste management authority can give you instructions on recycling and proper disposal For vertical mount put one screw top and one screw bottom For horizontal mount put o...

Страница 7: ...ule s subbase the same way you would wire a hardwired thermostat subbase For vertical mount put one screw top and one screw bottom For horizontal mount put one screw left and one screw right Horizonta...

Страница 8: ...factory to operate a conventional heating and cooling system This thermostat will also operate a heat pump system See the heat pump configuration step on page 12 of this manual to configure the thermo...

Страница 9: ...is reestablished The Blue LED on the base module will also turn off to show communication has been lost Note The Blue LED on the base module will be on when power is present The Blue LED will flash 3...

Страница 10: ...on The heating swing setting is adjustable from 0 2 F to 2 F For Example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approxi...

Страница 11: ...r nonprogrammable Program Options Select F for Fahrenheit temperature read out or select C for Celsius read out F for Fahrenheit C for Celsius F F or C The second stage will turn on at 2x the swing se...

Страница 12: ...enable the balance point tech setup option The cooling fan delay setting will delay the fan from coming on in cool mode and keep running after the compressor shuts off for a short time to save energy...

Страница 13: ...ep Then hold down the light button on the R251W until it beeps while in ZONE technician setup step on R251W To connect a second R251W change the T955W to read 2 and change the R251W to zone 2 The zone...

Страница 14: ...the thermostat or base module snaps in place On the back of the thermostat insert 2 AA Alkaline batteries included Battery installation is optional if there are no remotes connected to the Master Ther...

Страница 15: ...low to set the day of the week and current time Press MENU Press SET TIME Day of the week will be flashing Use the or key to select the current day of the week Press NEXT STEP The current hour is flas...

Страница 16: ...customized program schedule if using 5 1 1 Wake Leave Return Sleep Wake Leave Return Sleep Wake Leave Return Sleep Weekday Customize Your Program Saturday Sunday Day of the Week Setpoint Temperature...

Страница 17: ...period Repeat steps 4 through 7 for Saturday WAKE time period for Saturday LEAVE time period for Saturday RETURN time period and for Saturday SLEEP time period 1 2 3 4 5 6 7 8 9 Sunday Repeat steps 4...

Страница 18: ...as needed It is very important to make sure the cooling setpoint temperature is at least 3 above the heating setpoint temperature and that the heating setpoint temperature is at least 3 below the cool...

Страница 19: ...e Battery power from 2 AA Alkaline batteries 32 F to 105 F 0 to 41 C 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D 916 MHz 19 SPECIFICATIONS CONTACT INFORMATION Specifications Pro1 IAQ Inc 1111 S Gl...

Отзывы: