PROGRAMMING THE THERMOSTAT
17
Set 5+1+1 Program Schedule
To customize your 5+1+1 program schedule, follow these steps
Weekday:
Saturday:
Select
HEAT
or
COOL
using the
SYSTEM
key.
Note:
You have to program heat and cool each separately.
Press
MENU
Press
SET SCHED
. Note: Monday-Friday is displayed and the
WAKE
icon is shown. You are now
programming the
WAKE
time period for the weekday setting.
Time is flashing. Use the or key to make your time selection for the weekday
WAKE
time
period. Note: If you want the fan to run continuously during this time period, select
ON
with the
FAN
key.
Press
NEXT STEP
The setpoint temperature is flashing. Use the or key to make your setpoint selection for the
weekday
WAKE
period.
Press
NEXT STEP
Repeat steps 4 through 7 for weekday
LEAVE
time period, for weekday
RETURN
time period, and for
weekday
SLEEP
time period.
Repeat steps 4 through 7 for
Saturday
WAKE
time period, for
Saturday
LEAVE
time period, for
Saturday
RETURN
time period, and
for Saturday
SLEEP
time period.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Sunday:
Repeat steps 4 through 7 for
Sunday
WAKE
time period, for
Sunday
LEAVE
time period, for
Sunday
RETURN
time period, and
for Sunday
SLEEP
time period.
10.
Additional step if R251W indoor remote sensor is connected.
The
T955W
master thermostat will either average all sensors (system average) or only use
one sensor for the system ambient temperature (priority). The default setting is
SYSTEM
AVERAGE
, which means all sensors are averaged to create the system average ambient
temperature reading. The
NEXT ZONE
key can be pressed to change the priority.
The system information area of the display shows the priority.
For Example:
There is an
R251W
connected and it is named
REMOTE 1
. If the
NEXT
ZONE
key is pressed until
REMOTE 1
is shown, then the
REMOTE 1
ambient temperature
reading will be used exclusively for that time period. All other sensors will be ignored.