Sanitize Water on Water
This can be performed at the time of the filter replacement.
Place a towel down under the system for spills. Also have a small bucket available.
1.
With feed supply on, drain down about 20 seconds of water through the faucet, then
close the faucet.
2.
Giving it 10 seconds, the system should be de
-
pressurized by this time. The
“
PW/SQ
”
port will not have any pressure.
3.
Turn off supply to the
“
F
”
port.
4.
Remove the
“
PW
”
and the
“
SQ
”
pins.
5.
Install the sanitizer cannister (available online at www.wowwater.com) to the
“
PW
”
port,
using a ¼
”
tube, making sure the cannister has the sanitizing solution (3% Hydrogen Per-
oxide) inside. (This is important).
6.
Place ¼
”
tubing in the
“
SQ
”
port and direct
“
SQ
”
exit into a bucket or pot.
7.
Using the supply line to pressurize the sanitizer is best, so detach from the
“
F
”
port. Place
into the sani
-
cup and turn on supply for 10 seconds.
8.
You are now ready to turn on the feed valve to the sanitizer. Water will immediately em-
anate from the
“
SQ
”
port into the bucket. Leave on for about a liter/quart of water. You
have now introduced a sanitizer to the product water bladder.
9.
Next, remove sanitizer tube from
“
PW
”
port. Disengage feed line from sanitizer unit and
place back into
“
F
”
port. Plug the
“
PW
”
port. Remove
“
SQ
”
exhaust line and place plug
back in
“
SQ
”
port.
10.
Leave sanitizing solution in the system for about 2 hours, then open faucet and drain sys-
tem until empty. Then let system fill on its own.
Содержание WOW RO System
Страница 4: ...4 Figure 1 Installation Diagram...
Страница 5: ...5 Section 1 Installation Start up Procedures...
Страница 8: ...8 Installation Kit Contents A B C D E F G H I G...
Страница 17: ...17 Figure 7 Refrigerator Icemaker...
Страница 24: ...24 Modular Expandability Parallel Processing...
Страница 25: ...25 Section 4 Plumbing the Sink...
Страница 29: ...29 Section 5 Maintenance...
Страница 35: ...35 Section 6 Troubleshooting...