background image

15

 

The 

WOW RO System

 is uniquely designed to connect to one or more appliances (Figure 5), includ-

ing refrigerator icemakers/door dispensers, coolers (both gravity fed and pressurized), under

-

the

-

counter hot & cold vented systems, commercial steamers (restaurants), commercial coffee makers 
and other appliances that benefit from RO water. This section addresses 

Do

s and Don

ts

” 

of con-

necting  to  one  or  more  appliances.  It  also  addresses  how  to  determine  storage  and  expansion 
needs depending on how many appliances are hooked up.

 

General MUST Do

s for connecting ANY additional appliances:

 

A.

 

It

s a must that the filter and water lines to any and all added 

outlets be clear of air. Note:  System will not work with air in 
the lines.

 

B.

 

Close isolation lines to all additional outlets.

 

C.

 

Charge system to its full status (refer to Start

-

up, Page 13).

 

D.

 

Follow the instructions provided from Pages 16

-

22.

 

Determining Your Expansion and Storage Needs:

 

A standard 

WOW RO System

 holds 1½ gallons. The 

WOW RO System 

has been designed in a mod

-

ular format to add additional storage tanks as needed.

 

Review chart below for each device connected.  Add all additional tanks needed from right hand 
column to determine complete storage needs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

               

*

 Check device manual for actual reservoir capacity.

 

Connecting to Multiple Appliances

 

Device

 

Average Reservoir in

 

Gallons *

 

Estimated Additional Tanks 
Needed

 

Refrigerator / Icemaker

 

0 gallons

 

None

 

Commercial Coffee Maker

 

1 gallon

 

0

-

1

 

Depending on draw down 
needs at peak periods (See 
Page 14 for draw down defini-
tion).  Count glass/cups per 
hour to determine if greater 
than 1 gallon.

 

Gravity Cooler

 

Up to 3 gallons

 

1

 

Pressurized Cooler

 

Up to 3 gallons

 

1

 

Vented Hot Box

 

2/3 of a gallon or 84 oz.

 

0

 

Содержание WOW RO System

Страница 1: ...ER MANUAL for Undercounter WOW RO Systems 23880 Madison Street Torrance CA 90505 310 375 5000 www wowwater com V13 2 12 18 Powered by Scan with QR Reader App Visit our website www wowwater com Place D...

Страница 2: ...mix drinks fill batteries etc with treated water Caution The working capacity of this appliance depends on the pressure and temperature of the water supply This appliance is not guaranteed to work pro...

Страница 3: ...tem 14 Connecting to Multiple Appliances 15 Refrigerator Ice maker Coffee maker Cooler setup 16 21 Section 3 When More Water is Needed 22 Adding Extra Storage Tanks 23 Modular Expandability 24 Section...

Страница 4: ...4 Figure 1 Installation Diagram...

Страница 5: ...5 Section 1 Installation Start up Procedures...

Страница 6: ...ed outlets Without an isolation valve the WOW RO System will not start Refer to Section 2 for connecting additional appliances 5 Before beginning Start up Procedures Step 5 Page 13 make sure all tube...

Страница 7: ...d confirm 3 filter cartridges PRE POST RO 1 RO unit tank manifold and installation kit if purchased If installation kit is not purchased you will need 3 4 x 1 4 tubing 1 3 8 drain saddle sized for air...

Страница 8: ...8 Installation Kit Contents A B C D E F G H I G...

Страница 9: ...E Drain saddle 1 4 F Drain saddle 3 8 G 1 4 WOW RO emergency shut off valve H Feed water adapter I Tubing for install connections Black 3 8 Air gap return line to 3 8 drain saddle Black 1 4 Air gap d...

Страница 10: ...in place located in center Remove red cap on RO membrane Confirm that large external O Ring is in place Confirm that medium O Ring is in place Confirm that 2 small O Rings are in place located in cent...

Страница 11: ...d and no air is present at the top 4 Attach post filter in the labeled POST position RO membrane in the labeled RO position and the pre filter in the labeled PRE position with a twisting counter clock...

Страница 12: ...and the other end to gray F port See Figure 1 Page 4 Installation Diagram C Drain D connection i Air Gap Faucet Route the free end of the 1 4 black tubing attached to the RO faucet air gap to the conn...

Страница 13: ...pen RO faucet and empty system to a trickle At this point the system should have generated a full gallon and a half of water If not see Note 1 below or refer to Troubleshooting Guide Page 35 G Turn of...

Страница 14: ...ottles ex ceeding 1 gallons at same time additional storage will be required In addition devices with larger storage capacities like coolers will require greater draw down needs Draw down refers to am...

Страница 15: ...ll additional outlets C Charge system to its full status refer to Start up Page 13 D Follow the instructions provided from Pages 16 22 Determining Your Expansion and Storage Needs A standard WOW RO Sy...

Страница 16: ...g Lines Adding a refrigerator hook up from a pre installed WOW wet installation a Close feed water valve b Open faucet to relieve pressure on the FA ports c Remove the 3 8 plug from the FA1 port by pu...

Страница 17: ...17 Figure 7 Refrigerator Icemaker...

Страница 18: ...ion valve e Go to Start up Procedures Page 13 and proceed until fully operational f After start up open isolation valve and bleed line to coffee maker as described below Bleeding Lines Adding a coffee...

Страница 19: ...Close isolation valve e Go to Start up Procedures Page 13 and proceed until fully operational f After start up open isolation valve and bleed line to cooler as described below Bleeding Lines Adding a...

Страница 20: ...isolation valve e Go to Start up Procedures Page 13 and proceed until fully operational f After start up open isolation valve and bleed line to hot tank as described below Bleeding Lines Adding a hot...

Страница 21: ...21 Figure 8 A Ice maker Coffee maker Water Cooler Figure 8 B Hot Tank Vented Faucet Installation Isolation Valve To Faucet To Water Cooler To Coffee Maker To Icemaker...

Страница 22: ...dard WOW RO System holds 1 gallons The WOW RO System has been de signed in a modular format to add additional storage tanks as needed Review chart below for each device connected Add all additional ta...

Страница 23: ...ed to the spare tank See Figure 9 below for one or multi ple tank set ups f Connect green tubing between the matching PW ports on the manifold and the adapter See Figure 9 below for one or multiple ta...

Страница 24: ...24 Modular Expandability Parallel Processing...

Страница 25: ...25 Section 4 Plumbing the Sink...

Страница 26: ...ction of the drain saddle See Figure 11 D Make sure to align the drain saddle to the drilled hole use small screwdriver to check align ment E Attach the drain saddle to the drain pipe and tighten the...

Страница 27: ...ructions Drilling a porcelain clad steel or cast iron sink Caution Be careful when the drill is about to penetrate the base metal of the sink Reduce the speed and support the drill so the drill chuck...

Страница 28: ...Reconnect the riser tube to the other end of the incoming water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop cannot be made See Figure 13 E F...

Страница 29: ...29 Section 5 Maintenance...

Страница 30: ...er cartridges 2 With a black permanent marker write the date on each filter to track replacement time Filters last up to a year in most cases 3 Pre fill all cartridges with bottled water or tap water...

Страница 31: ...d filters should be replaced depends upon the quality of the water that enters the appliance Contact your WOW Water specialist or visit www wowwater com for replacement filters and parts Note The inst...

Страница 32: ...the WOW RO system This low energy technology significantly reduces nearly every category of undesirable water contaminants as small as 1 100 000 000 one hundred millionth of an inch This includes ino...

Страница 33: ...gen Per oxide inside This is important 6 Place tubing in the SQ port and direct SQ exit into a bucket or pot 7 Using the supply line to pressurize the sanitizer is best so detach from the F port Place...

Страница 34: ...asing Reverse Osmosis A Practical Application Manual for Residential Point of Use Systems by Robert Slovak one of the members of the TOPPER development team This publication can be purchased directly...

Страница 35: ...35 Section 6 Troubleshooting...

Страница 36: ...water is needed Sec tion 3 Page 22 Water dispensing does not meet average flows Not enough water pressure Pre filter is plugged House regulator may need to be increased or add a pump Change filter Se...

Страница 37: ...change post filter Match filter with proper position on RO unit Change post filter Water leaking from Air Gap installa tion Air gap installation incorrect Clogged drain Remove loops or sags from Air G...

Страница 38: ...ecom mended to use only microbiological safe water with your WOW RO System appliance Caution Do not use water that is microbiologically unsafe or of unknown quality without adequate disin fection befo...

Страница 39: ...are not covered by this warranty We assume no warranty liability in connection with this Reverse Osmosis System other than as specified herein This warranty is in lieu of all other warranties expresse...

Отзывы: