background image

C260

GENERAL REMARKS AND SAFETY -2

INSTALLATION AND USE INSTRUCTIONS

5

GENERAL INSTRUCTIONS

• 

Before installing and using the actuator, it is compulsory that the installer and the user carefully read and understand this manual in 

all its parts.

• 

This manual is integral part of the actuator and must compulsorily be preserved for future reference.

• 

The manufacturer has no liability for any eventual damage to persons, animals and things due to the inobservance of the prescrip-

tions described in this manual.

• 

In order for the automation unit to operate correctly, we recommend carrying out periodical maintenance on it, as indicated in this 

manual.

• 

The warranty on the actuator will not be honored if product is not installed and used according to the instructions provided and the 

regulations shown in this instruction manual and if it is used with non genuine parts, accessories, spare parts and/or control/feeding 

units.

INSTALLER AND USER

• 

The actuator installation can be performed exclusively by competent and qualifi ed technical personnel satisfying the professional 

and technical requirements foreseen by the laws in force in the country of installation.

• 

The installation technician shall accept full responsibility for any installation errors and for any failure to adhere to the instructions 

provided in this manual. The installation technician shall therefore be exclusively liable for any damages caused to users and/or third 

parties that may arise as a result of incorrect installation.

• 

The actuator can be used exclusively by a user acting in compliance with the instructions contained in this manual and/or in the 

manual of the actuator control device (e.g.: control unit).

TECHNICAL ASSISTANCE

• 

Contact the installation technician or retailer for assistance.

RESERVED RIGHTS

• 

The reserved rights on this manual “Installation and use instructions” remain property of the Manufacturer.

• 

Each information herein contained (text, drawings, diagrams, etc.) is reserved.

• 

None part of this manual can be reproduced and disclosed (totally or partially) by any reproduction means (photocopies, microfi lms 

or other) without written authorization of the Manufacturer.

DESCRIPTION OF PERSONNEL

USERS MUST NEVER PERFORM OPERATIONS RESERVED FOR MAINTENANCE PEOPLE OR SPECIALISED TECHNI-

CIANS. THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGE DERIVING FROM FAILURE TO OBSERVE THE 

ABOVE REQUIREMENTS.

Specialised electrician:

A specialised electrician must be able to install the actuator, start it and operate it both in normal conditions and in the maintenance mode; 

he/she is qualifi ed to perform all electrical and mechanical adjustment and maintenance operations. He/she is allowed to work on live 

electrical cabinets and junction boxes.

User:

specialised person capable of operating the actuator under normal conditions by using the relative controls. He/she must also be able to 

operate with the actuator under “maintenance” in order to perform simple routine maintenance operations (cleaning), and start or reset 

the actuator following an unscheduled stop

SAFETY GENERAL INSTRUCTIONS

• 

Operators must be informed of accident risks, safety devices and the general accident prevention regulations established by in-

ternational directives and by the law in force in the country of use. All operators must strictly comply with the accident prevention 

regulations in force in the country of use.

• 

Do not remove or alter the plates placed on the actuator by the manufacturer.

• 

If the window frame is accessible from or installed at a height of less than 2.5 m from the ground, and if it can be commanded by 

an untrained user or with a remote control device, fi t an emergency stop system which automatically cuts in to prevent the risk of 

crushing or dragging parts of the body inserted between the moving and fi xed parts of the window frame.

• 

Do not operate dome windows in the presence of a load of snow in excess of the quantity declared acceptable by the window man-

ufacturer.

• 

Any tampering with or unauthorized replacement of one or more parts or components of the actuator, or the use of unoriginal acces-

sories and consumables, may increase the risk of accident and thus relieves the manufacturer of all civil and penal liability.

• 

The maintenance operations involving the total or partial dismounting of the actuator may only be performed after disconnecting it 

from the power supply.

• 

This appliance may not be used by persons (children included) with reduced physical, sensorial or mental capacities, or inexpert 

people, unless they are supervised and taught how to use it by a person responsible for their safety. 

• 

Children must be controlled to make sure they do not play with the appliance.

• 

During handling and installation of the parts, the personnel shall be equipped with suitable personal protection equipment (PPE) so 

as to perform the works required under safe conditions.

SAFETY DEVICES - PROTECTION AGAINST ELECTRIC HAZARD

• 

The actuator is protected against electric hazard due to direct and indirect contacts.

• 

The protection measures against direct contacts aim at protecting people against hazards due to contact with active parts, usually 

live parts; while the protection measures against indirect contacts aim at protecting people against hazards due to conducing part, 

which are usually insulated, but could become live in case of failure (insulation failure).

The adopted protection measures are the following:

1) Insulation of live parts by means of a plastic material body;

2) Enclosure with suitable protection degree;

3)C260 equipped with double insulation: Protection of passive type given by the use of components with double insulation, also called 

components of class II or with equivalent insulation. (It is forbidden to connect the actuators equipped with double insulation to the earth 

plant.

Содержание C260

Страница 1: ... FOR WINDOW AUTOMATION EN BEFORE INSTALLING AND USING THE ACTUATOR IT IS COMPULSORY FOR THE INSTALLER AND THE USER TO READ AND UNDERSTAND THIS MANUAL IN ALL ITS PARTS THIS MANUAL IS INTEGRAL PART OF THE ACTUATOR AND MUST BE PRESERVED FOR FUTURE REFERENCE UNTIL DEMOLITION OF THE SAME ...

Страница 2: ......

Страница 3: ...COMPONENTS PAG 9 APPLICATIONS PAG 11 TOP HUNG outward opening application PAG 14 BOTTOM HUNG outward opening application PAG 16 BOTTOM HUNG inward opening application PAG 18 VERTICAL outward opening application PAG 20 ACTUATOR ON LEAF inward opening application PAG 22 SIDE HUNG Outward opening PAG 24 SIDE HUNG Inward open PAG 27 ELECTRICAL CONNECTIONS PAG 30 INDEX ...

Страница 4: ...INSTALLATION AND USE INSTRUCTIONS 4 C260 EC DECLARATION OF INCORPORATION ...

Страница 5: ...mal conditions by using the relative controls He she must also be able to operate with the actuator under maintenance in order to perform simple routine maintenance operations cleaning and start or reset the actuator following an unscheduled stop SAFETY GENERAL INSTRUCTIONS Operators must be informed of accident risks safety devices and the general accident prevention regulations established by in...

Страница 6: ...g type model serial number and year of construction of the actuator In case of replacement of the power supply cable it is necessary to use a cable type h05 vvf 3 x 0 75 The replacement can be performed exclusively by competent and qualified technical personnel meeting the professional and tech nical requirements foreseen by the laws in force in the country of installation MAINTENANCE If the actuat...

Страница 7: ...ontrol device the user has to compulsory occupy a safe control position assuring visual control on the window movement It is compulsory to verify constantly in time the functional efficiency and the rated performance of the actuator of the window frame where it is installed and of the electric plant performing when necessary interventions of routine or supplementary maintenance assuring operation co...

Страница 8: ...he actuator out of reach of children RATING PLATE AND CE MARKING The CE marking certifies the compliance of the machine with the essential safety and health requirements foreseen by the product European Directives The rating plate is an adhesive plate in polyester silk screen printed in black having the following size L 24 mm H 60 mm It is applied externally on the actuator The plate bears in reada...

Страница 9: ...C260 TECHNICAL DESCRIPTION 3 INSTALLATION AND USE INSTRUCTIONS 9 COMPONENTS A B C D E ...

Страница 10: ...INSTALLATION AND USE INSTRUCTIONS 10 3 TECHNICAL DESCRIPTION C260 COMPONENTS DIMENSIONING ...

Страница 11: ... application S3 SG M2 1000 VERTICAL outward opening application S4 SH M1 800 SIDE HUNG outward opening application LEFT S2 SF PF M1 600 SIDE HUNG outward ope ning application RIGHT S4 SF PF M1 600 SIDE HUNG inward opening application LEFT S3 SF LF M2 1000 SIDE HUNG inward opening application RIGHT S3 SF PF M2 1000 ON LEAF On the window inward opening application S4 SD M1 950 Distance from the open...

Страница 12: ...ables must be properly sized according to the absorbed electric power see rating plate and CE marking Any type of electric material plug cable terminals etc Used for the connection must be suitable for the use with CE marking and complying with the requirements foreseen by the laws in force in the country of installation To assure an efficient separation from the mains it is compulsory to install up...

Страница 13: ...d to the window to avoid damaging it If this happens in the last 50mm of the movement which is below the allowable maximum overlap you might find that the window remains slightly open the next time it is closed You only need to briefly open and close the window a few times about 4times to activate the system and restore the window to its correct and proper closure Detailed description for restoratio...

Страница 14: ...INSTALLATION AND USE INSTRUCTIONS 14 5 INSTALLATION INSTRUCTIONS FIGURE C260 Stroke 600 230V Standard TOP HUNG outward opening application Double push point ...

Страница 15: ... connections according to the provisions as well as with reference to the wiring diagram Power the actuator and let the chain come out for at least 250mm of stroke then disconnect the actuator 7 8 First fasten the LEFT chain terminal to the S2 first fit the long side of the shaft and then in sert the entire assembly Move the square plate to the centre of the mount and hand tighten bolt A Now insert ...

Страница 16: ...INSTALLATION AND USE INSTRUCTIONS 16 5 INSTALLATION INSTRUCTIONS FIGURE C260 Stroke 600 230V Standard BOTTOM HUNG outward opening application Double push point ...

Страница 17: ...c connections accor ding to the provisions as well as with reference to the wiring diagram Power the actuator and let the chain come out for at least 250mm of stroke then disconnect the actuator 7 8 First fasten the RIGHT chain terminal to the S2 first fit the long side of the shaft and then in sert the entire assembly Move the square plate to the centre of the mount and hand tighten bolt A Now inse...

Страница 18: ...INSTALLATION AND USE INSTRUCTIONS 18 5 INSTALLATION INSTRUCTIONS FIGURE C260 Stroke 600 230V Standard BOTTOM HUNG Inward opening Double push point ...

Страница 19: ...ndow brackets are correctly fastened to their clamps 7 Perform the electric connections according to the wiring diagram Power the actuator and let the chain come out for at least 150mm of stroke then disconnect the actuator Fit the actuator into the clamps M2 through the tracks on the actuator Centre the chain end on the bottom hinged bracket 8 Fasten the chain terminal to the bottomhinged Bracket...

Страница 20: ...INSTALLATION AND USE INSTRUCTIONS 20 5 INSTALLATION INSTRUCTIONS FIGUR C260 Stroke 600 230V Standard VERTICAL outward opening application Double push point ...

Страница 21: ... to the provisions as well as with reference to the wiring diagram Power the actuator and let the chain come out for at least 250mm of stroke then disconnect the actuator 6 First fasten the RIGHT chain terminal to the S4 first fit the long side of the shaft and then insert the entire assembly Move the square pla te to the centre of the mount and hand tighten bolt A Now insert bolt B included into th...

Страница 22: ...INSTALLATION AND USE INSTRUCTIONS 22 5 INSTALLATION INSTRUCTIONS FIGURE C260 Stroke 600 230V Standard ON LEAF inward opening application Double push point ...

Страница 23: ...ic connections according to the provisions as well as with reference to the wiring diagram Power the actuator and let the chain come out for at least 250mm of stroke then di sconnect the actuator 7 8 First fasten the LEFT chain terminal to the S4 first fit the long side of the shaft and then insert the entire assembly Move the square pla te to the centre of the mount and hand tighten bolt A Now inse...

Страница 24: ...INSTALLATION AND USE INSTRUCTIONS 24 Stroke 600 230V Standard SIDE HUNG outward opening application SIDE HUNG outward opening application 5 INSTALLATION INSTRUCTIONS FIGURE C260 ...

Страница 25: ...ISTRUZIONI PER L INSTALLAZIONE E L USO 25 C260 5 INSTALLATION INSTRUCTIONS FIGURE ...

Страница 26: ...ring diagram Power the actuator and let the chain come out for at least 250mm of stroke then disconnect electri cally the actuator 7 8 First fasten the UPPER chain terminal to the S2 S4 first fit the long side of the shaft and then insert the entire assembly Move the square pla te to the centre of the mount and hand tighten bolt A Now insert bolt B included into the fra me mount and tighten both bol...

Страница 27: ...INSTALLATION AND USE INSTRUCTIONS 27 Stroke 600 230V Standard SIDE HUNG inward opening application SIDE HUNG inward opening application C260 5 INSTALLATION INSTRUCTIONS FIGURE ...

Страница 28: ...ISTRUZIONI PER L INSTALLAZIONE E L USO 28 5 INSTALLATION INSTRUCTIONS FIGURE C260 ...

Страница 29: ...Perform the electric connections according to the wiring diagram Power the actuator and let the chain come out for at least 150mm of stroke then disconnect the actuator Fit the actuator into the clamps M2 through the tracks on the actuator Centre the chain end on the bottom hinged bracket Fasten the chain terminal to the bottomhinged Bracket S3 wing with the screw and nut provi ded in the package ...

Страница 30: ...INSTALLATION AND USE INSTRUCTIONS 30 C260 6 ELECTRICAL CONNECTIONS ...

Страница 31: ......

Страница 32: ...TOPP S r l Società a Socio Unico soggetta a direzione e coordinamento di 2 Plus 3 Holding S p a Via Galvani 59 36066 Sandrigo VI Italia Tel 39 0444 656700 Fax 39 0444 656701 Info topp it www topp it ...

Отзывы: