Page 69 of
93
Serial Communication Control
In default working mode, the camera is able to connect to a VISCA controller with an RS232C serial interface.
RS232 Communication Control
The camera can be controlled via RS232. The parameters of RS232C are as follows:
Baud rate: 2400, 4800, 9600 or 38400 bps.
Start bit:
1 bit.
Data bit:
8 bits.
Stop bit:
1 bit.
Parity bit:
none.
RS485 Communication Control
The camera can be controlled via RS485, Half-duplex mode, with support for VISCA, Pelco-D or Pelco-P protocol.
The parameters of RS485 are as follows:
Baud rate: 2400, 4800, 9600 or 38400 bps.
Start bit:
1 bit.
Data bit:
8 bits.
Stop bit:
1 bit.
Parity bit:
none.