background image

1

Safety Installation Information

1. READ and FOLLOW all instruction.
2.

The gate opener is intended for use with Class I vehicular

swing gates.
Class I denotes a vehicular gate opener (or system) dwellings,
or a garage or parking area associated therewith.
Install the gate opener only when the opener is appropriate for
the construction and the usage class of the gate.
3.

Gate opening system designers, installers and users must

take into account the possible hazards associated with each
individual application. Improperly designed, installed or
maintained systems can create risks for the user as well as the
bystander. Gate system design and installation must reduce
public exposure to potential hazards. All exposed pinch points
must be eliminated or guarded.
4.

A gate opener can create high levels of force during

normal operation. Therefore, safety features must be
incorporated into every installation. Specific safety features
include safety sensors.
5.

The gate must be properly installed and work freely in

both directions prior to the installation of the gate opener.
6.

The gate must be installed in a location so that enough

clearance is provided between the gate and adjacent structure
when opening and closing to reduce the risk of entrapment.
Swinging gates shall not open into public access areas.
7.

The opener is intended for use only on gates used for

vehicles. Pedestrians must be supplied with a separate access
opening. The pedestrian access opening shall be designed to
promote pedestrian usage. The pedestrian access shall be
located such that persons will not come in contact with the
moving vehicular gate.

8.

Pedestrians should never cross the pathway of a moving

gate. The gate opener is not acceptable for use on any
pedestrian gate. Pedestrians must be supplied with a separate
pedestrian access.
9.

For an installation utilizing non-contact sensors (safety

sensors), see product manual on the placement of non-contact
sensors (safety sensors) for each type of application.

a.

Care shall be exercised to reduce the risk of nuisance

tripping, such as when a vehicle trips the safety sensor while
the gate is still moving.
b.

One or more non-contact sensors (safety sensors) shall

be located where the risk of entrapment of obstruction exists,
such as the perimeter reachable by a moving gate or barrier.
10. Never mount any device that operates the gate opener
where the user can reach over, under, around or through the
gate to operate the controls. Controls are to be placed at least 6’
(1.8m) from any part of the moving gate.

11. Controls intended to be used to reset an operator after 2
sequential activations of the entrapment protection device or
devices must be located in the line of sight of the gate, or easily
accessible controls shall have a security feature to prevent
unauthorized use. Never allow anyone to hang on or ride the
gate during the entire travel of the gate.
12. Each gate opener is provided with two safety warning
placards. The placards are to be installed on the front and back
of the gate where they are plainly visible. The placards may be
mounted using cable ties through the four holes provided on
each placard.
All warning signs and placards must be installed where visible
in the area of the gate.

13. To AVOID damaging gas, power, or other underground
utility lines, contact underground utility locating companies
BEFORE digging.

14.

Do not permit children to play on or around the gate and

keep all controls out of their reach.
15. SAVE INSTRUCTION.

Содержание MT9012

Страница 1: ...ens com MT9012 VER 22b C030615 Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the ba...

Страница 2: ...n ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Country Regio...

Страница 3: ...tion for Installation 7 Install the Opener on the Gate for Pull to Open 7 Install the Opener on the Gate for Push to Open 10 Mounting the Control Box 13 Connection of the Power Supply 14 Connecting of...

Страница 4: ...ould never cross the pathway of a moving gate The gate opener is not acceptable for use on any pedestrian gate Pedestrians must be supplied with a separate pedestrian access 9 For an installation util...

Страница 5: ...eway gates made by steel wood vinyl and shaped as panel tube and chain link While use on solid surface gates is NOT recommended Solid surface gates have a high resistance to the wind If the wind is st...

Страница 6: ...3 MT9012 Parts List Extra parts for rounded gate post...

Страница 7: ...rol with Camera TC186 WiFi Smartphone Remote Control with Camera TKP3 Wireless Keypad TC175P Wired Keypad TEW3 Vehicle Sensor Exit Wand HLR01 HomeLink Remote Control Kit TC173 Wireless Push Button TC1...

Страница 8: ...tion Class IP44 NOTE NR indicates this size and weight combination is NOT recommended for one arm actuator NOTE Ball bearing hinges should be used on all gates weighing over 140kg 300 lbs 550 kg 1200...

Страница 9: ...g Reverse in case of obstruction during gate closing Built in adjustable auto close 0 99 seconds Built in max Motor running time MRT adjustable for multiple safety protection 1 50 seconds Digital disp...

Страница 10: ...cket to the gate post via pipe clamps requires the diameter of the gate post should be less than or equal to 80mm Install the Opener on the Gate for Pull to Open The position of Post Bracket is very i...

Страница 11: ...0 counterclockwise 4 With the opener fully retracted and with the gate in the fully open position for Pull to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate...

Страница 12: ...ions 8 Attach the post bracket assemblies to the gate posts by using four expansion bolts 9 Attach the gate brackets to each gate by inserting two M8x80 bolts through the gate brackets and the drilled...

Страница 13: ...stallation Install the Opener on the Gate for Push to Open The position of Post Bracket is very important The following illustrations and tables are required to determine the proper mounting position...

Страница 14: ...counterclockwise 4 With the opener fully retracted and with the gate in the fully closed position for Push to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gat...

Страница 15: ...ons 8 Attach the post bracket assemblies to the gate posts by using four expansion bolts 9 Attach the gate brackets to each gate by inserting two M8x80 bolts through the gate brackets and the drilled...

Страница 16: ...control box is waterproof designed for safety reason and a longer service life it is recommended to install the control box inside a secure surface and at least 100 cm 40 inches above the ground to a...

Страница 17: ...gh rightmost strain relief Then repeat step 2 NOTE Only motor cables 1 5m length are provided Other cables are subject to site installation requirement and not provided Connection of the Power Supply...

Страница 18: ...15 Connecting of the Control Board...

Страница 19: ...he battery should be wired to the BAT 13 terminal 24V should be wired to BAT 14 terminal The battery could also be charged by the solar panel solar controller Please refer to the manual instruction of...

Страница 20: ...l The BLACK wire of the external receiver should be connected into the 20 terminal The RED wire of the external receiver should be connected into the 9 terminal Wired Keypad 24VDC optional The RED wir...

Страница 21: ...ram it with our swing gate opener Every press of the button is able to active the gate opener to work alternately open stop close stop open 2 Use one remote to operate TOPENS swing gate opener sliding...

Страница 22: ...Always ask the help of professional technician electrician if you have any question 1 Check again for completed and correct assembly of your swing gate opener and gate Plug the Power Cord into the ne...

Страница 23: ...and the Master gate starts to open 1 more second earlier Each time you press and release the DEC button the figure decreases by 1 and the interval decreases by 1 second Factory set is 3 seconds Press...

Страница 24: ...MRT of MOTOR2 When the Digital Display indicates P8 you can adjust the MRT of MOTOR2 Please perform the same procedure as adjusting MOTOR1 7 a Press the FUNC button to store the data when you finish...

Страница 25: ...t 16 sec 23 3 4 16 sec 12 Return to Factory Set When the Digital Display indicates Pd press and release the INC or DEC button All data will return to factory set the Digital Display indicates dF 13 If...

Страница 26: ...Check your installation periodically as hardware and posts will shift Brackets may need to be adjusted or hardware may need to be tightened 4 Maintain the area around your gate Keep the areas free of...

Страница 27: ...short Gate opens but does not close 1 Photocell PBS function is enabled in control board setting but is not equipped optional Please cancel the PBS setting P9 set to 00 2 Obstruction blocking close ph...

Страница 28: ...25 Quick Setting Guide...

Страница 29: ...26...

Страница 30: ...27...

Страница 31: ...28...

Страница 32: ...you have any need to contact us the info below will help you get in touch TOPENS Website www topens com Contact Us E mail support topens com Kindly include your Product Model Purchasing Date Site Ord...

Отзывы: