Motor connection for PULL-TO-OPEN
Actuator 1 (for PULL-TO-OPEN)
Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The
red
wire
should be inserted into the “
”
terminal, the
black
wire into “
MOTOR1-“
, the
blue
wire into
ULT1
, the
green
wire into
COM
, and the
yellow
wire into
DLT1
terminal.
Actuator 2 (for PULL-TO-OPEN)
Similar as the connection of
Actuator 1
, insert the stripped cable wires into the appropriate terminals on the
opener terminals block. The
red
wire should be inserted into the
terminal, the
black
wire into
MOTOR2-
, the
blue
wire into
ULT2
, the
green
wire into
COM
, and the
yellow
wire into
DLT2
terminal.
NOTE:
It is recommended that Gate Opener 1 is installed in the Master Gate, and Gate Opener 2 is installed in
the Slave Gate.
Warning Light (Included in some models, refers to the actual package)
The red wire of the warning light should be inserted into
+LAMP (#11)
terminal, the white wire into the
LAMP-
(#12)
.
Back-up Battery & Solar Panel & Solar Controller (optional)
If there is
no solar panel
to be used for charging the battery, then the
“24V+”
of the battery should be wired to
the
BAT+ (#13)
terminal.
“24V-”
should be wired to
“BAT-” (#14)
terminal.
The battery could also be charged by the solar panel & solar controller. Please refer to the manual instruction of
solar panel and controller separated for wire connection.
Photocell Beam System (PBS)
(Included in some models, refers to the actual package)
Use a 2-core cable to connect the
“- ~”
terminal of the photocell’s emitter to the “14” terminal, the
“+ ~”
terminal
to the “9” terminal. Also the
“- ~”
and
“+ ~”
terminals of the photocell’s receiver should be connected to the “14
and “9” terminals in parallel.
Use another 2-core cable to connect the
“COM”
terminal of the receiver to the “17” terminal, the
“NC”
terminal
to the “18” terminal.
Push Button (optional)
The push button should be wired to the “19” and “20” terminals. The gate operator works alternately by pushing
Motor connection for PUSH-TO-OPEN
The motors’ power wires and limit wires connection by
“Push to Open”
is different from the connection by
“Pull
to Open”
. So motor 1 and motor 2 wires should be
connected to the control box as the instruction on the right.
The
black
wire should be inserted into the Motor+ terminal,
the
red
wire should be inserted into the Motor- terminal, the
yellow
wire into ULT1 terminal, the
blue
wire into DLT1
terminal and the
green
wire is still into COM terminal.