14
DIP Switch #2: ON
– 4 Seconds
OFF
– 0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled. The midway mode could be activated by pressing button B of the remote
control when the gate is in the full closed position.
DIP Switch #3–#5: Fine adjust the soft stop period of the motor
DIP Switch #3: ON
– 1 Second
OFF
– 0
DIP Switch #4: ON
– 2 Seconds
OFF
– 0
DIP Switch #5: ON
– 3 Seconds
OFF
– 0
NOTE: Every time you restart the gate opener after power off, you should use the access control
device (such as remote, push button and etc.) to operate the gate opener to run for a complete
opening cycle and a complete closing cycle to get the full opening time and the full closing time. You
would achieve the soft stop in your next opening/closing cycle. Factory default soft stop time is 3
Second. You can turn the DIP switches on/off to fine adjust the soft stop time to meet your actual
needs.
DIP Switch #6–#7: Auto close time of the gate opener
DIP Switch #6: ON
– 30 Seconds
OFF
– 0
DIP Switch #7: ON
– 60 Seconds
OFF
– 0
NOTE: The auto close function would be disabled if both DIP switches are turned to off (factory
default setting).
DIP Switch #8: Left/Right open
E.g. Running time of the opener in midway mode is 2+4=6 seconds.
E.g. The soft stop period of the motor is 1+2=3 seconds.
E.g. Auto close time of the gate opener is 30+60=90 seconds.
Содержание DK1000
Страница 5: ...4 Parts List Extra Parts Rev 20a...