10
1. Cut off the wire which has been connected between terminal 4 and 5 in factory to deactivate the existed
short circuit of terminal 4 and 5.
2. Solder the two wires to the terminals of the switch respectively.
NOTE: The power supply cord is not included in the package.
NOTE: Make sure a residual current circuit breaker with a 30mA threshold is fitted before the power
supply mains.
NOTE: The protection class of the emergency stop switch should be at least IP44.
Connecting of the Batteries & Solar Panels & Solar Controller
WARNING: NEVER connect the gate opener to the power outlet before all the installations have
been done.
NOTE:
1. The batteries (ONLY included in Y Series) can be used as back-up power or main power. The wire
connection is different for the two conditions.
2. If batteries as are chosen as the power source, Marine or Automotive Type Battery is required. The
batteries should be waterproof type, or be placed in water proof circumstance.
3. 2 PCS 12VDC batteries can be connected in series to function as 24VDC. The following diagram
shows on how to connect 2 PCS batteries in series. Charging mode for the battery could be only by
the solar panel OR both of the solar panel and the AC electricity at the same time.
4. Please note that the wire connection of the power supply system is very important. Incorrect wire
connection will damage the control board.
1. Using with the AC electricity at the same time
The gate opener can be powered by the AC electricity and the batteries at the same time. The batteries are
used as back-up power source in case of AC power failure. In this situation, 5AH batteries are enough if the
power failure time is less than 8 hours per day. Please connect the batteries & the solar panels & solar
controller refer to the following illustration.
Содержание DK1000
Страница 5: ...4 Parts List Extra Parts Rev 20a...