background image

Section 5—Installation

5.1 Pre-Installation Inspection

5.2 Pre-work Preparation

When unpacking, please carefully confirm the following points: 

 

● 

Whether the accessories are missing according to the packing list.

 

● 

Whether there is any damage during transportation. 

● 

Whether the model and specification of the machine's nameplate are consistent with the order requirements.

When transporting or moving the EV charger, pay attention to the following points to ensure product safety: 

 In order to ensure the long-term stable operation of the product, it is recommended to avoid installing 

chargers in extreme weather, especially as low or high ambient temperatures may affect the installation effect 

due to thermal expansion and cold contraction.

The electrical power supply socket (NEMA 14-50R) must be prepared.

Space requirement: When the charger is fixed on the wall, the minimum space requirements are shown in Fig. 

5.2. (Only for hardwired installation)
It is suggested that the charger should be installed in a place with good ventilation, no direct sunlight and 

shelter from wind and rain. In order to ensure good ventilation, mount the charger vertically with clear space 

around all sides.

Fig. 5.2 Minimum space requirements for wall mounting

(Only for hardwired installation)

If any damage or missing parts are found, please do not start the installation, and contact us as soon 

as possible.

Please keep the packing box and packing materials for 1 month for future handling.

The paper packaging is recyclable.

This product is electrical equipment. It should be handled with care, avoiding violent vibration and 

impact.
The charger shall not be transported by dragging the charging connector and the charging cable.

17

200mm

(min)

200mm

(min)

200mm

(min)

≈1200-1400mm

Содержание PulseQ AC Home US Version

Страница 1: ...AC EV Charger User Manual US Version ...

Страница 2: ......

Страница 3: ...Section 6 Network Configuration Section 7 LED Indicators Section 8 Fault Handling Section 9 Warranty Section 10 FCC 3 4 10 12 16 17 29 36 37 38 39 IEC EV EVSE OBC KW A V Hz LCD LED 1 2 3 4 5 6 7 8 9 10 Human Machine Interface Charging Circuit Interrupting Device Ground Monitor Interrupter Ground Fault Circuit Interrupter HMI CCID GM I GFCI 13 14 15 16 Central Management System manages EVSE and has...

Страница 4: ...t fingers into the electric vehicle connector Do not use this product if the flexible power cord or EV cable is frayed has broken insulation or has any other signs of damage Do not use this product if the enclosure or the EV connector is broken cracked open or shows any other indication of damage Note the ambient temperature rating 22 F to 131 F 30 C to 55 C CAUTION To reduce the risk of fire conn...

Страница 5: ...ouch in case of ESD Indicates possible consequences of touching electrostatically sensitive components No access for unauthorized persons Use protective footwear Must wear a safety helmet Indicates important texts notes or tips 1 2 SAFETY NOTES Safety protection must be worn when installing the EV Charger Installation must be performed carefully due to risk of electric shock Must be installed vert...

Страница 6: ...ables are defective cracked worn broken or the charging cables is exposed If you find any please contact the supplier in time 1 2 4 Safety Precautions for Maintenance Personnel must always use protective footwear when performing maintenance work It is recommended that Charger is routinely inspected at least once a week Do not put inflammable explosive or combustible materials chemicals combustible...

Страница 7: ...ecteur du véhicule électrique N utilisez pas ce produit si le cordon d alimentation flexible ou le câble EV est effiloché a une isolation cassée ou tout autre signe de dommage N utilisez pas ce produit si le boîtier ou le connecteur EV est cassé fissuré ouvert ou montre toute autre indication de dommage Indiquez la température ambiante de 30 C à 55 C Note actuelle Modèle 50 A PULSEQ AC HOME MISE E...

Страница 8: ...aux obligatoires et panneaux d information suivants sont utilisés dans le manuel d utilisation sur et dans la station de charge M3P EV MISE EN GARDE Avertissement de risques électriques Ce signe est destiné à alerter l utilisateur que des blessures graves ou des dommages matériels importants peuvent survenir si l appareil n est pas utilisé comme demandé ATTENTION Avertissement d un point de danger...

Страница 9: ... produits chimiques des vapeurs inflammables à proximité des chargeurs faute de quoi il y a un risque d incendie Le véhicule électrique ne peut être rechargé que si le moteur est éteint et statique Il ne faut pas recharger les jours de pluie et les orages L utilisation de chargeur est strictement interdite lorsque l adaptateur de charge ou le câble de charge présente des défauts des défauts des dé...

Страница 10: ...AC Level 2 charging According to IEC 61851 1 the Charging mode of PulseQ AC Home is Mode 3 and charging connection is the Case C Mode 3 a method for the connection of an EV to an AC EV supply equipment permanently connected to an AC supply network with a control pilot function that extends from the AC EV supply equipment to the EV Case C Connection of an EV to a supply network utilizing a cable an...

Страница 11: ...ulseQ AC Home product meets SAE J1772 IEC 62196 2 Type 1 PulseQ AC Home provides a Type 1 female plug with charging cable it only chargs an EV with a Type 1 charging socket vehicle inlet Fig 2 4 1 Schematic diagram of Type 1 interface L1 PE L2 CP CS ...

Страница 12: ... AC Home charger are shown as Fig 3 1 1 The block diagram of PulseQ AC Home charger is shown as Fig 3 2 1 LED INDICATOR CCID Wifi 2 4GHz NAMA 14 50P Ethernet R 45 Type 1 plug Type 1 socket of EV NAMA 14 50R Fig 3 1 1 The shape dimensions of PulseQ AC Home Fig 3 2 1 Block Diagram 220mm 310mm 95mm Main CPU ...

Страница 13: ...o connect terminal G Ground Plug NEMA 14 50P Cable 4 8 AWG 300mm copper PULSEQ AC HOME Model Number Rated Voltage Rated Current Rated Power Safety Protection CCID built in Input plug cable Charging interface Mode 3 Remote APP controlled Local Plug and charge 4 LED lights Indicate 4 statuses including standby charging fault and network WiFi 2 4GHz Ethernet RJ 45 interface And support OCPP 1 6J Prot...

Страница 14: ...trique ou d incendie nepas utiliser de rallonge aveccet appareil Risk of explosion This equipment has arcing or sparking parts that should not be exposed to flammable vapors This equipment should be located at least 460 mm 18 inches above the floor Risk of explosion This equipment has internal arcing or sparking parts which should not be exposed to flammable vapors It should not be located in a re...

Страница 15: ...Max 40A 55 240VAC 60Hz Max 40A 55 Type 4 22 F to 131 F 30 C to 55 C The suitability of the use of flexible cord in accordance with CE code Part I Rule 4 012 is to be determined by the local inspection authority having jurisdiction Risk of electric shock Do not remove cover or attempt to open the enclosure No user serviceable parts inside Refer servicing to qualified service personnel C est à l aut...

Страница 16: ...arging Dock Wall mounting Accessories User Manual Quick User Guide Quality Certificate Wall Installation Template M6 63mm Expansion Bolt M5 40mm Expansion Bolt Charging Dock Installation Template IC card 1 1 1 1 1 1 1 4 4 1 2 a b c d e f g h i j k a g d e f j c b h i 16 User Manual k IC card ...

Страница 17: ... NEMA 14 50R must be prepared Space requirement When the charger is fixed on the wall the minimum space requirements are shown in Fig 5 2 Only for hardwired installation It is suggested that the charger should be installed in a place with good ventilation no direct sunlight and shelter from wind and rain In order to ensure good ventilation mount the charger vertically with clear space around all s...

Страница 18: ...he voltage Multimeter 1 Fastening bolt Wrench 3 Peeling cables Wire stripper 5 Drill fixing holes in the wall Electric Impact drill 2 Cut the cable Diagonal plier 4 Pressed cable terminal Crimping plier 6 Fastening screw Crimp the RJ45 connector Phillips screwdriver RJ45 Crimper 7 8 No Tools Name Schematic Picture Main Uses 18 ...

Страница 19: ...n from the ground adjacent to the stud where the charging station will be mounted See Fig 5 4 2 Refer to the Fig 5 4 3 to understand the dimensions of the wall bracket Please make sure the space on the wall is at least 5 62 5 98 143mm 152mm Fig 5 4 1 Fig 5 4 2 Fig 5 4 3 1 2 1 WARNING In areas with frequent thunderstorms add surge protection at the service panel for all circuits Ensure all power an...

Страница 20: ...ith the installation template See Fig 5 4 4 Drill the mounting holes on the wall with a depth of at least 1 97 See Fig 5 4 5 Hammer the expansion sleeve into the corresponding hole See Fig 5 4 6 2 3 3 Fig 5 4 4 Fig 5 4 5 Fig 5 4 6 1 97 20 ...

Страница 21: ...has been fixed on the wall Consult an electrician for any NEMA 14 50 installation questions Determine the plug type purchased by the homeowner The NEMA 14 50 is required See Fig 5 5 1 Hang the charging station to the wall bracket and fasten the bolts on the each side See Fig 5 5 2 Plug in the charging cable and start the initial charge 1 2 3 Fig 5 5 1 Fig 5 4 7 Fig 5 5 2 21 ...

Страница 22: ...the terminal block See Fig 5 6 2 L1 L2 PE 2 Fig 5 6 2 5 6 Hardwire Installation The hardwire installation needs to be done by electricians and please strictly follow the safety precautions Remove the four screws on the back cover with a Phillips screwdriver See Fig 5 6 1 1 Fig 5 6 1 22 ...

Страница 23: ...E L1 L2 PE Unscrew the bolts at the bottom of the charging station See Fig 5 6 3 You can use a large wrench if needed 3 Fig 5 6 3 Take out the cable wire and remove the magnet ring See Fig 5 6 4 4 Fig 5 6 4 23 ...

Страница 24: ...river and take the back cover off See Fig 5 6 5 There is another bolt hidden underneath the UL certification label Please remove the lable to unscrew the bolt 5 Fig 5 6 5 Unscrew the cable clip and take out the cable from the bottom hole See Fig 5 6 6 6 Fig 5 6 6 24 ...

Страница 25: ... right bottom hole See Fig 5 6 8 Ensure the service wiring can easily reach the connectors on the charging station s input terminal block Fully insert the wires into the connectors on the terminal block with the ground wire on the right Tighten the screws with a torque of 1 8 Nm See Fig 5 6 9 8 9 10 Fig 5 6 7 Fig 5 6 8 Fig 5 6 9 25 ...

Страница 26: ...work plug Fig 5 7 1 1 2 3 Before inserting the power input cable you can deform the service wire with crimping plier Insert the exposed wires into the corresponding holes pushing the cables up until the silver conductors are no longer visible 5 7 Network Cable Installation We strongly recommend that you use a Wi Fi network when conditions permit Please refer to Section 6 or the Quick User Guide fo...

Страница 27: ... 54mm 54mm Drill the mounting holes on the wall with a depth of at least 1 97 See Fig 5 8 2 Place the installation template on the wall and mark the mounting hole See Fig 5 8 1 1 2 2 3 5 8 Charging Dock Installation 54mm 54mm Fig 5 8 1 Fig 5 8 2 at least 1 97 27 ...

Страница 28: ...ket into the charing dock See Fig 5 8 3 Fix the charging dock on the wall with the expansion screw in the package See Fig 5 8 4 4 5 Please put the charging plug back to the Charging Dock after each charge Fig 5 8 3 Fig 5 8 4 28 ...

Страница 29: ...install the app to your phone See Figure 6 1 1 Fig 6 1 1 Register an account with your email address and login See Figure 6 1 2 Open the app and tap the User Center select Charging Station Management See Figure 6 1 3 1 2 3 Section 6 Network Configuration Fig 6 1 2 Fig 6 1 3 6 1 Wi Fi Configuration 29 ...

Страница 30: ...Tap the cross at the bottom right to add your charging station See Figure 6 1 4 Select the Wi Fi network See Figure 6 1 5 4 5 Fig 6 1 4 Fig 6 1 5 30 ...

Страница 31: ...Tap the TOPDON AC Home to connect the hotspot See Figure 6 1 6 Tap the Wi Fi Setting enter the Wi Fi name and password to set up the connection See Figure 6 1 7 6 7 Fig 6 1 6 Fig 6 1 7 31 ...

Страница 32: ...Once the above steps have been done tap Confirm to complete the procedure See Figure 6 1 8 8 Fig 6 1 8 32 ...

Страница 33: ...and tap the User Center select Charging Station Management See Figure 6 2 1 Tap the cross at the bottom right to add your charging station See Figure 6 2 2 1 2 6 2 Wired Network Configuration Fig 6 2 1 Fig 6 2 3 33 ...

Страница 34: ...Select the Ethernet Setting See Figure 6 2 3 Please read the note carefully and tap Next See Figure 6 2 4 3 4 Fig 6 2 3 Fig 6 2 4 34 ...

Страница 35: ...an the QR code which is attached on the charging station See Figure 6 2 5 5 The above steps can only be carried out after the ethernet cable is installed to the charging station Fig 6 2 5 35 Scan QR code ...

Страница 36: ...d fault status Twinkle Unconnected network OFF Fault status BLN control Exchanging data with CMS via network ON Configure WiFi network status Twinkle Charging status 1 3 2 4 No Icon Indicator Color Indicator Status Connotation The LED indicators on the panel are used to indicate the status of the charger and the various combinations of indicators are described below 36 ...

Страница 37: ...g charging cable and EV socket are damaged or wet Power off disconnect and reconnect the charging plug and restart Check whether the charging plug and its cables are damaged or wet Check whether the charging connector is correctly connected Check whether the OBC is normal Check the set of output maximum current Battery of EV is full or the charging plug is not properly connected Disconnect and rec...

Страница 38: ...fects reported during the Warranty Period TOPDON will either repair or replace the defective part or product according to its technical support analysis and confirmation TOPDON shall not be liable for any incidental or consequential damages arising from the device s use misuse or mounting Some states do not allow limitation on how long an implied warranty lasts so the above limitations may not app...

Страница 39: ... one connected to the receiver Consult a dealer or an experienced radio TV technician for help FCC Caution This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The user manual or instruc...

Страница 40: ...SUPPORT TOPDON US ...