![Topcon TP-L6 Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/topcon/tp-l6-series/tp-l6-series_instruction-manual_1128670057.webp)
54
13. SPECIFICATIONS
• Battery using time will vary depending on environmental conditions and operations done with TP-L6W
series.
Charger (CDC77)
Input voltage
100 to 240 V AC
Charging time (at 25°C per battery)
BDC72
About 8 hours (Charging may take longer than this at low or high
temperature.)
Range of charging temperature
0 to 40°C (32 to 104 °F)
Range of storage temperature
-20 to 65°C (-4 to 149 °F)
Dimensions
94 (W) X 102 (D) X 36 (H) mm
Weight
About 250 g
Operating temperature range
-20 to 50°C (-4 to 122 °F)
Storage temperature range
-30 to 60°C (-22 to 140 °F)
Water resistance
IPX8 (IEC 60529:2001) (when the battery holder is attached)
Size
125mm X 250mm (without handle)
125mm X 280mm (with rear handle)
Weight
about 3.0kg (with BDC72)
Remote controller Model RC-500
Operating distance
Though the pipe from a forward position, about 200m (656ft.)
From above panel, about 25m (82ft.)
Functions
Line control, Laser beam ON/OFF, Laser beam mode,
Centerline LED, Upper/Lower laser switch, Automatic alignment mode,
Line centering
Power supply
Two AA size dry batteries
Working duration at 20°C (68°F)
about 8 months (Using manganese dry batteries)
Water resistance
IPX6 (IEC 60529:2001)
Size
59(W) X 27(D) X 154(H)mm
Weight
about 170g (with batteries)